User guide
Table Of Contents
- Chapter 1: Introduction
- Chapter 2: Installation
- Chapter 3: Operation – User Functions
- Chapter 4: Operation – Administrator Functions
- The Administration Menu
- Guidelines for System Configuration
- System Configuration
- Video Redirection (Forced Video)
- Channel Association for Multiple Video
- User Configuration
- Channel Configuration
- User Station Profile
- Group Settings (Access Rights)
- Recommendations
- System Reboot and System Reset
- Network Settings
- Autoscan and Autoskip
- Power Management
- Paragon II Network Port
- Chapter 5: Paragon II and P2ZCIMs/Z-CIMs
- Chapter 6: Managing IBM BladeCenter Servers
- Chapter 7: Configurations
- Chapter 8: Firmware Upgrade
- Appendix A: Specifications
- Appendix B: User Station Direct Mode
- Appendix C: Tiering and Compatibility
- Appendix D: Paragon II Rack Mount
- Appendix E: Connecting Serial Devices to Paragon II System
- Appendix F: Extra Keyboard/Mouse Information and Settings
- Appendix G: Recommendation for Better Video Quality
- Appendix H: Other Components Working with Paragon II
- Appendix I: Troubleshooting

78 PARAGON II USER GUIDE
Paragon II and Z-CIMs
Z-CIM installation requires that servers are assigned names when added to the Z-CIM chain. The
default name of any Z-CIM is its serial number, which is not meaningful to you. In order to name
the Z-CIM, it must be connected to a server that is powered on and to the matrix switch’s to get
status and name assignment.
To organize and track Z-CIMs and the servers to which they are connected, we recommend one
of two methods:
• Record the serial numbers of the Z-CIMs connected to each server, and then name all
Z-CIMs at one time once the chain is complete.
• First complete the chain and then power on the Z-CIMs one at a time, checking the serial
number on the Z-CIM as it is connected, and assigning the proper name to the proper server
Z-CIM.
When naming or renaming a Z-CIM, switch to that Z-CIM to activate it, thereby ensuring that its
new name is updated in the matrix switch’s database.
Connecting Z-CIMs as Tiers
The following diagram shows setup guidelines for connecting Z-Series Z4200U Z-CIMs
(UKVMSPD):
IN OUT PC
Last Z-CIM
or P2ZCIM
Z-CIM Terminator
Z-CIM
C
a
t
5
e
C
a
t
5
e
C
a
e
t
5
Servers
Up to 42
U
K
V
M
S
P
D
U
K
V
M
S
P
D
U
K
V
M
S
P
D
C
a
e
t
5
C
a
e
t
5
Back of P2-UMT832
UKVMSPD,
UKVMSC,
or P2ZCIM
(up to 42)
UKVMSPD,
UKVMSC,
or P2ZCIM
P2ZCIM or
Figure 73 Connecting Z-CIMs or P2ZCIMs as Tiers
All Paragon II components must be powered ON prior to Z-CIM tier installation. All servers and
components in the Z-CIM chain must be powered OFF prior to installation.
When following the installation and configuration instructions below, sort the Selection Menu by
channel number, not by name. Display the menu by pressing the F2 key on your keyboard and
change the sorting method by pressing the F12 key.