User guide
Table Of Contents
- Chapter 1: Introduction
- Chapter 2: Installation
- Chapter 3: Operation – User Functions
- Chapter 4: Operation – Administrator Functions
- The Administration Menu
- Guidelines for System Configuration
- System Configuration
- Video Redirection (Forced Video)
- Channel Association for Multiple Video
- User Configuration
- Channel Configuration
- User Station Profile
- Group Settings (Access Rights)
- Recommendations
- System Reboot and System Reset
- Network Settings
- Autoscan and Autoskip
- Power Management
- Paragon II Network Port
- Chapter 5: Paragon II and P2ZCIMs/Z-CIMs
- Chapter 6: Managing IBM BladeCenter Servers
- Chapter 7: Configurations
- Chapter 8: Firmware Upgrade
- Appendix A: Specifications
- Appendix B: User Station Direct Mode
- Appendix C: Tiering and Compatibility
- Appendix D: Paragon II Rack Mount
- Appendix E: Connecting Serial Devices to Paragon II System
- Appendix F: Extra Keyboard/Mouse Information and Settings
- Appendix G: Recommendation for Better Video Quality
- Appendix H: Other Components Working with Paragon II
- Appendix I: Troubleshooting

CHAPTER 5: PARAGON II AND P2ZCIMS/Z-CIMS 77
9. Press S to refresh the chain.
on Menu and verify that channel order of the chain have been
Important: Please follow the guideline here to ensure that there is enough power to
10. Press F2 to go to the Selecti
refreshed.
support all P2ZCIMs in a chain.
For Paragon I UMT242, 442, 832 d
and Paragon II matrix switches; in chains up to 20 individual P2ZCIM units at least one
P2ZCIM must be powered ON; In P2ZCIMs chains from 21 to 42 ZCIM units, at least 15
P2ZCIMs must be powered ON.
an 1664 with hardware III and Paragon II firmware,
P2ZCIM LED Status
The LED on each P2ZCIM indicates its operational state:
• If the LED blinks rapidly: P2ZCIM does not have a confirmed Communication Address.
med
board/mouse traffic: CIM has a
Note: The P2ZCIM will blink from time to time even if there is no keyboard/mouse traffic;
• If the LED is primarily off and blinks on every two (2) seconds: P2ZCIM has a confir
Communication Address but is not switched to that Address.
• If the LED is on and blinks on/off rapidly when there is key
confirmed Communication Address and is switched to that Address.
this demonstrates that the P2ZCIM is operating normally and not locked.
• If the LED is blinking on and off but at a regulated, moderate speed (i.e., every half second):
that P2ZCIM is acting as Manager of the chain.