User guide
Table Of Contents
- Chapter 1: Introduction
- Chapter 2: Installation
- Chapter 3: Operation – User Functions
- Chapter 4: Operation – Administrator Functions
- The Administration Menu
- Guidelines for System Configuration
- System Configuration
- Video Redirection (Forced Video)
- Channel Association for Multiple Video
- User Configuration
- Channel Configuration
- User Station Profile
- Group Settings (Access Rights)
- Recommendations
- System Reboot and System Reset
- Network Settings
- Autoscan and Autoskip
- Power Management
- Paragon II Network Port
- Chapter 5: Paragon II and P2ZCIMs/Z-CIMs
- Chapter 6: Managing IBM BladeCenter Servers
- Chapter 7: Configurations
- Chapter 8: Firmware Upgrade
- Appendix A: Specifications
- Appendix B: User Station Direct Mode
- Appendix C: Tiering and Compatibility
- Appendix D: Paragon II Rack Mount
- Appendix E: Connecting Serial Devices to Paragon II System
- Appendix F: Extra Keyboard/Mouse Information and Settings
- Appendix G: Recommendation for Better Video Quality
- Appendix H: Other Components Working with Paragon II
- Appendix I: Troubleshooting

CHAPTER 7: CONFIGURATIONS 95
Non-Standard Tier Configuration
Guidelines for Existing Firmware Versions
Non-Standard tier configurations are those configurations supported by Paragon II, but require
special procedures in order to function properly. These include:
• Triangle Configuration
• Single Diamond Configuration
• Redundant Configuration
Recovery:
− After any re-connection subsequent to the Non-Standard tier configuration, all UMTs
should undergo a FUNC reset to clear the database. See Reset Unit under Paragon II
Front Panel Display and Controls in Chapter 2 for more information on clearing the
database. This procedure should be performed starting from the third-tier device down to
the Base Unit.
− Whenever a third-tier UMT is replaced, all of the second-tier and base UMTs should
undergo a FUNC reset.
− Whenever a second-tier UMT is replaced, all of the base UMTs should undergo a FUNC
reset.
− Whenever a base UMT is replaced, only the new UMT should undergo a FUNC reset.
−
Triangle Configuration
The following procedure must be followed to ensure this configuration functions properly:
After re-connection, all UMTs must undergo a FUNC reset to clear the switch database. See
Reset Unit under Paragon II Front Panel Display and Controls in Chapter 2 for more
information on clearing the database. This procedure should be performed starting from the
third-tier device down to the Base Unit.
− Execute the FUNC reset in the following order: UMT-3A → UMT-2A → UMT-Base 1.
UMT
-
3A
UMT
-
2A
UMT
-
Base 1
Figure 89 Triangle Configuration