For UKVMSC Z-CIM with local port:
a. Connect DB25 male end of CCPnn cable to DB25 female port on back of a Z-CIM (UKVMSC).
b. Connect other end to computer’s keyboard, video, and mouse ports.
c. Place the Z-CIM Terminator in the Z-CIM’s UTP IN port.
d. Power ON computer.
e. Optional: Connect a local user console to the UKVMSC Z-CIM.
Perform Channel Configuration:
1. At a User Station Login Menu, type admin in the User Name field and press Enter.
2. Type “raritan” (all lowercase) in the Password field and press Enter.
3. Press F5 to go the Administration Menu and select the Channel Configuration submenu.
4. Use the and or the Page Up and Page Down keys to highlight the Paragon II channel where the
Z-CIM was just added.
5. Ensure that the Device field reads Zseries.
6. If Zseries does not appear in the Device field:
a. Press Tab until the Device field is active, them press Enter - the highlight will turn green.
b. Use the and keys to change device type to Z-Series and press Enter - the green highlight will
return to yellow.
c. Press S to save the change, or press Esc to exit without saving.
7. If a more descriptive name is desired:
a. Hold the Shift key and press Tab to go back to the Name column, then press Enter - the highlight
will turn blue.
b. Edit the default name and press Enter - the highlight will turn green as you begin to type.
c. Press S to save the change, or press Esc to exit without saving.
8. Press F2 to go to the Selection Menu to validate that the second-tier Z-CIM is properly configured.
Select the tiered Z-CIM device and press Enter.
Name the Computer Channel on the Z-CIM tiered Selection Menu:
1. When viewing the Paragon II Selection Menu or any OSUI menu, press F5 to go to the Administration
Menu.
2. Select the Channel Configuration submenu.
3. Select the Z-CIM device channel.
4. Press G to bring up a Channel Configuration menu for the Z-CIM chain.
5. Use the and keys to highlight the Name field of the computer just connected via Z-CIM. The
channel for this computer is displayed in green, and the highlight will turn yellow when it is selected.
6. Press Enter - the highlight will turn blue.
7. Type the desired computer name - the highlight will turn green as you begin to type.
8. Press Enter - the highlight will turn yellow.
9. Press S to save the new name.
Verify and Save Changes:
1. Press F2 to return to the Selection Menu.
2. The Selection Menu will display with the new computer name highlighted in white.
3. Press Enter to switch to this selected computer.
4. Normal computer access and operation indicates a successful connection.
Note: Repeat the steps on the previous pages:
Connect Z-CIMs as a Tier
Perform Channel Configuration
Name the Computer Channel on the Z-CIM tiered Selection Menu
Verify and Save Changes
for each server to be added to the chain. Name and test each computer as it is added. Follow the steps
below to build the rest of the Z-CIM chain of servers.