User manual

20 PARAGON II USER MANUAL
b. Assign the Stacking Unit ID using the and keys.
6. Press the ENT button (sequential order is not necessary).
7. Power OFF all units.
8. Power ON the Stacking Unit.
9. Power ON the Main Switching Unit.
Installing a HubPac
The Paragon HubPac (part number P2HUBPAC) expands user access capability to a maximum of 64 users.
Each HubPac is capable of connecting 16 servers to 4 Paragon Matrix Switch units.
CIM models capable of connecting to a HubPac include:
P2CIM-PS2
P2CIM-SUN
P2CIM-USBG2
Figure 26 Paragon HubPac
Installing a HubPac
Please use the Basic Installation instructions that follow to create 32-user Paragon Matrix Switching
configuration.
UserStation
(1-8)
1IN
1-1 1-2 1-3 1-4
UserStation UserStation UserStation UserStation UserStation UserStation UserStation
ENT
FUNC
ESC
ENT
FUNC
ESC
ENT
FUNC
ESC
ENT
FUNC
ESC
(1-8) (1-8)
(1-8)
(Users 1-8) (Users 9-16) (Users 17-24) (Users 25-32)
Up to 32 Users Per Server
Back of HubPac
5IN
5-1 5-2 5-3 5-4
6IN
6-1 6-2 6-3 6-4
7IN
7-1 7-2 7-3 7-4
8IN
8-1 8-2 8-3 8-4
1IN
1-1 1-2 1-3 1-4
2IN
2-1 2-2 2-3 2-4
3IN
3-1 3-2 3-3 3-4
4IN
4-1 4-2 4-3 4-4
AC Power
115V/230V
60Hz/50Hz
AC IN
0.6A/0.3A
On Off
Server
UKVMP
Cat 5e Cable
UMT832
USTI
Cat 5e Cable
Cat 5e Cable
Figure 27 Connecting a P2-UMT832M to a HubPac
1. Power OFF each Paragon switch
Note: Prior to installation all Paragon switch units and HubPac units must be powered OFF. Computers
and User Stations (UST1s) to be connected can be in a powered ON state.