6 PARAGON II USER MANUAL
6. Connect one end of a Category 5e UTP cable to Channel Port #1 on the back of the Main Switching
Unit (or Stacking Unit, if attached). Connect the other end of the cable to the RJ45 port on a Computer
Interface Module (P2-CIM).
7. Connect the P2-CIM to server’s keyboard, video, and mouse ports.
8. Power ON server.
9. Repeat steps 3 through 8 for all other CPUs you want to attach.
Initial Administrative Testing
To verify that an attached server can be viewed and controlled through the Paragon system:
1. When you first power ON the Paragon Base Unit, an attached User Station, and the User Station’s
attached monitor; a Login Menu will be displayed on the monitor. Type admin (all lowercase) in the
User Name field and press the Enter key. Type raritan (all lowercase) in the Password field and
press the Enter key.
Note: The factory-default user names are user01 through up to user16 (depending on the model of the Base
Unit) for regular users and admin for the admin user. User names are not case-sensitive. By default, a
password is required only for the admin user, and that password is raritan. Passwords are case-sensitive.
Figure 4 Login Menu
2. The monitor will display an On-Screen User Interface (OSUI) Selection Menu with the port of the
connected CPU displayed in green. (It will have no default name – the Name field will be blank.)
Figure 5 Selection Menu