User guide
Chapter 3: Installation
13
5. Type a new password, and then retype it (Remember this password).
A page opens, showing the Dominion SX unit's status and serial
channel ports.
Note: If the password entered does not follow the password rules, an
error message will appear as a warning. You will be logged out and
must start over to set your password.
Network Access
1. Ensure that the installation computer has the route for 192.168.0.192
and that it can communicate with IP address 192.168.0.192.
2. To check the route table in Windows
®
, type the command route print
in a Command window on the installation computer. If 192.168.0.192
is on the gateway list, proceed to step 3. Otherwise, add
192.168.0.192 to the gateway list using the appropriate DOS or
UNIX
®
CLI command:
Windows 98/2000/NT system: route add 192.168.0.192
<INSTALLATION COMPUTER IP ADDRESS>.
[Example: route add 192.168.0.192 15.128.122.12]
UNIX (including Sun Solaris) system:
route add 192.168.0.192 <CLIENT_HOST IP ADDRESS>
-interface.
[Example: route add 192.168.0.192 15.128.122.12
-interface]
3. Type ping 192.168.0.192. Go to step 4 if you receive a
successful reply from the Dominion SX unit. If an error occurs, verify
that the default IP address is entered correctly and that a route to
that IP address exists.
4. Use the installation computer to connect to the unit by launching a
browser and typing the factory default IP address 192.168.0.192 in
the Web browser's address bar.
Set Date and Time
1. Type Configuration to change the unit's configuration.
2. Type Time to select the Date / Time configuration.
3. Type Timezonelist and find the numerical code that corresponds
to your time zone.
4. Type clock [tz timezone] [datetime datetime-string]. For
example:
admin > Config > Time > clock tz 9 datetime "2007-02-05
09:22:33"
In this example, 9 is the time zone code (Step 3) and "2007-02-05
09:22:33" the date/time string in the format "YYYY-MM-DD