User guide
Chapter 13: Command Line Interface
176
ipmitool
Command
Description
[-o <oemtype>]
Select OEM type to support. This usually involves minor
hacks in place in the code to work around quirks in
various BMCs from various manufacturers. Use -o list to
see a list of current supported OEM types.
[-C <ciphersuite
>]
The remote server authentication, integrity, and
encryption algorithms to use for IPMIv2 lanplus
connections. See table 22-19 in the IPMIv2
specification. The default is 3 which specifies
RAKP-HMAC-SHA1 authentication, HMAC-SHA1-96
integrity, and AES-CBC-128 encryption algorithms.
<command>
raw - Send a RAW IPMI request and print response
i2c - Send an I2C Master Write-Read command and
print response
lan - Configure LAN Channels
chassis - Get chassis status and set power state
power - Shortcut to chassis power commands
event - Send pre-defined events to MC
mc - Management Controller status and global enables
sdr - Print Sensor Data Repository entries and readings
sensor - Print detailed sensor information
fru - Print built-in FRU and scan SDR for FRU locators
sel - Print System Event Log (SEL)
pef - Configure Platform Event Filtering (PEF)
sol - Configure and connect IPMIv2.0 Serial-over-LAN
tsol - Configure and connect with Tyan IPMIv1.5
Serial-over-LAN
isol - Configure IPMIv1.5 Serial-over-LAN
user - Configure Management Controller users
channel - Configure Management Controller channels
session - Print session information
firewall - Configure firmware firewall (IPMIv2.0)
sunoem - OEM Commands for Sun servers
picmg - Run a PICMG/ATCA extended cmd
fwum - Update IPMC using Kontron OEM Firmware
Update Manager