User guide

Chapter 1: How to - Dominion SX Essentials
xviii
2. Choose the Port Access Tab, and click the port name you wish to
access, for example, Port 1.
3. Select YES to proceed through security warning(s).
4. The Raritan Serial Console (RSC) will be launched in a separate
window - press the Enter key to "wake up" session.
5. Type in target system's native commands in the RSC
window/console.
6. Choose Emulator > Exit. Click YES on the confirmation dialog to
exit and the RSC window will close.
See Raritan Serial Console (on page 48) for details.
Case 9. Port Configuration
These steps allow you to configure SX serial ports to set up correct serial
communications parameters (for example, baud rate, data bits, stop bit,
flow control) and terminal emulation mode to match the serial targets
connected to the ports, and name the ports to more easily identify the
targets.
To configure SX serial ports to set up correct serial
communications parameters:
1. Log in to SX via a web browser with your login username and
password, such as (admin/raritan).
2. Choose Setup > Port Configuration, check the box associated with
the port number you wish to configure, and click Edit.
See Port Configuration (on page 44) for details.
Case 10. CLI / SSH Connection to SX Port
To access the SX unit and SX ports using text-based command
lines:
1. SSH access from a Windows
®
PC:
a. Launch the SSH client software (such as Plink or PuTTY).
b. Enter IP address of SX server (for example, 192.168.0.192) and
the TCP port if applicable.
c. Select SSH (using default configuration port 22), and click Open.
d. Enter username and password when prompted: login as:
admin password: raritan (default value)