User guide

Chapter 13: Command Line Interface
126
Date and Time Configuration
Note: It is important to set the date and time correctly to ensure that log
entries and events contain the correct timestamp.
Return to the top menu level by entering the top command. Use the
following command to view the current date and time settings:
Admin Port > Config > Time > clock
The system displays the current settings. For example:
Date /Time Settings:
Date : 2006-09-20 23:20:24
Timezone : 13
Use the following steps to set the user date and time.
1. Admin Port > Config > Time > timezonelist
2. Admin Port > Config > Time > clock tz 21 datetime
"2006-09-23 13:22:33"
Setting Network Parameters
Network parameters are configured using the interface command.
Admin Port > Config > Network > dhcp false interface enable
true if lan1 ip 192.16.151.12 mask 255.255.255 gw
192.168.51.12
When the command is accepted, the unit automatically reboots and
drops the connection. You must reconnect to the unit using the new IP
address and the username admin and password newp/w entered in the
resetting factory default password section.
Important: If the password is forgotten, the Dominion SX must be
reset to factory default from the reset button on the rear panel and
the initial configuration tasks must be performed again.
The Dominion SX now has the basic configuration and can be accessed
remotely via SSH, GUI or locally using the local serial port. Next, you
must configure the users and groups, services, security, and serial ports
to which the serial targets are attached to the Dominion SX.