User guide

Chapter 13: Command Line Interface
121
Local Port Connection to the Dominion SX
If your Dominion SX's terminal port uses an RJ45 jack, a special cable
(CRLVR) is used with an ASCSDB9F connector on the client machine.
The CRLVR may also be used if RJ45-RJ45 connection to local port is
established - that is, if you connect the local port of a Dominion SX
device as a serial target to another Dominion SX.
Port Settings
Ensure that the port settings (serial communication parameters) are
configured as follows:
Data bits = 8
Parity = None
Stop bits =1
Flow Control = None
Connection
To make a local port connection:
1. Open a HyperTerminal application or equivalent.
2. Ensure the HyperTerminal is configured to communicate with the
port that is connected to the Dominion SX unit.
3. Disable Flow control.
4. Press the Enter key and the following prompt appears: user name
See Login (on page 119) for details.
To Change the Local Port Parameters:
The local port is enabled by default and is enabled on both serial ports
for units with two local ports at 9600 bps.
To change the local port parameters:
As an example, to change the baud rate from the default 9600 bps to
115200 bps, type:
Admin Port > Config > Services > lpa enable true bps
115200
To disable local port access:
Admin Port > Config > Services > lpa enable false