Specifications

70 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE
Delete a PowerStrip Connected to a KX, KX2, or P2SC Device
You cannot delete a PowerStrip connected to a KX or KX2 device from CC-SG. You must
physically disconnect the PowerStrip from the KX or KX2 device to delete the PowerStrip from
CC-SG. When you physically disconnect the PowerStrip from a KX or KX2 device, the
PowerStrip and all configured outlets disappear from the Devices tab.
Configuring PowerStrips Connected to SX 3.0 and KSX
You can perform the following tasks in CC-SG to configure and manage PowerStrips connected
to SX 3.0 or KSX devices.
Note: PowerStrips must be physically connected to the Power Port of a KSX device.
Add a PowerStrip Connected to an SX 3.0 or KSX Device
Delete a PowerStrip Connected to an SX 3.0 or KSX Device
Change a PowerStrip’s Device or Port Association (SX 3.0, KSX)
Add a PowerStrip Connected to an SX 3.0 or KSX device
1.
Add the SX 3.0 or KSX device to CC-SG.
2. On the Devices menu, click Device Manager, Add Device.
3. Select PowerStrip from the Device type drop-down menu.
Figure 64 Adding a PowerStrip device
3. Type a name for the PowerStrip in the Power Strip Name field. Hold your cursor over the
field to see the number of characters allowed in the name. Spaces are not permitted.
4. Click the Number of Outlets drop-down menu and select the number of outlets this
PowerStrip contains.
5. Click the Managing Device drop-down menu, and then select the SX 3.0 or KSX device that
is connected to this power strip.