Specifications
CHAPTER 6: POWER CONTROL 69
Chapter 6: Configuring Power Control
In CC-SG, PowerStrips must be connected to one of the following devices:
• Dominion KX
• Dominion KX2
• Dominion SX 3.0
• Dominion SX 3.1
• Dominion KSX
• Paragon II System Controller (P2SC)
To configure PowerStrips in CC-SG , you must know which Raritan device the powerstrip is
connected to physically.
Process for Configuring Power Control in CC-SG
• Complete all physical connections between the device, the powerstrip, and the nodes that are
powered by the powerstrip. Please refer to the RPC Quick Setup Guide, Dominion PX Quick
Setup Guide, and CC-SG Deployment Guide for details on physical connections between
PowerStrips, devices, and nodes.
• Add the managing device to CC-SG. The procedure varies for different Raritan devices.
Please refer to the section that corresponds to the device to which the PowerStrip is connected:
•
Configuring PowerStrips Connected to KX, KX2, and P2SC
•
Configuring PowerStrips Connected to SX 3.0 and KSX
•
Configuring PowerStrips Connected to SX 3.1.
•
Configure outlets.
• Associate each outlet with the node that it powers by
adding a Managed PowerStrip
interface to the node.
Configuring PowerStrips Connected to KX, KX2, and P2SC
CC-SG automatically detects PowerStrips connected to KX and KX2 devices. You can perform
the following tasks in CC-SG to configure and manage PowerStrips connected to KX and KX2
devices.
• Add a PowerStrip Device Connected to a KX or KX2 Device
• Move a KX or KX2’s PowerStrip to a Different Port
• Delete a PowerStrip Connected to a KX or KX2 Device
Add a PowerStrip Device Connected to a KX, KX2, or P2SC Device
When you add a KX or KX2 device that is connected to a PowerStrip to CC-SG, the PowerStrip
is added automatically. The PowerStrip will display in the Devices tab, beneath the KX or KX2
device that it is connected to.
Move a KX, KX2, or P2SC’s PowerStrip to a Different Port
When you physically move a PowerStrip from one KX, KX2, or P2SC device or port to another
KX, KX2, or P2SC device or port, CC-SG automatically detects the PowerStrip and updates its
association to the correct device. You do not have to add the PowerStrip to CC-SG separately.
Note: When you physically remove a PowerStrip from a P2SC port, but you do not connect it to
another port, CC-SG does not remove the PowerStrip from the old port. You must perform a
partial or full database reset of the UMT to which the PowerStrip is connected to remove the
PowerStrip from the Devices tab. Please refer to the Raritan