Specifications
Chapter 14: System Maintenance
232
CC-SG Shutdown
Shutting down CC-SG shuts down the CC-SG software, but it does not
power off the CC-SG unit.
After CC-SG shuts down, all users are logged out. Users cannot log back
in until you restart CC-SG, either via the Diagnostic Console or by
recycling the CC-SG power.
To shutdown CC-SG:
1. Choose System Maintenance > Shutdown CommandCenter.
2. Type your password in the Password field.
3. Accept the default message or type a message to display to any
users currently online in the Broadcast message field (for example,
you might give users a brief time period to finish their tasks in CC-SG
and tell them when they can expect the system to be functional
again). All users will be disconnected when you shut down CC-SG.
4. Type the number of minutes (from 0-720) that should pass before
CC-SG shuts down in the Shutdown after (min) field.
If specifying over 10 minutes, the broadcast message displays to
users immediately, and then repeats at 10 and 5 minutes before the
event occurs.
5. Click OK to shut down CC-SG.
Restarting CC-SG after Shutdown
After shutting down CC-SG, use one of these two methods to restart the
unit:
Use the Diagnostic Console. See Restart CC-SG with Diagnostic
Console (on page 310).
Recycle the power to your CC-SG unit.
Powering Down CC-SG
If CC-SG loses AC power while it is up and running, it will remember the
last power state. Once AC power is restored, CC-SG automatically
reboots. However, if CC-SG loses AC power when it is powered off, it will
remain powered off when AC power is restored.
Important: Do not hold the POWER button to forcibly power down
CC-SG. The recommended way to power down CC-SG is to use the
Diagnostic Console's "CC-SG System Power OFF" command. See
Power Off CC-SG System from Diagnostic Console
(on page 312).