Redundant Configuration 
These configurations are simply more complex Diamond configurations, and might be used to 
ensure redundancy; every switch is configured to another, in case of individual system failure. 
The procedure outlined below must be followed to ensure this configuration functions 
properly: 
−  After installation, all UMT Matrix Switches should undergo a FUNC reset to clear the 
switch database. This procedure should be performed starting from the third tier device 
down to the base unit. 
−  Execute the FUNC reset in the following order: UMT-3A → UMT-3B → UMT-2A → 
UMT-2B → UMT-Base 1 → UMT-Base 2. 
−  Whenever a third tier UMT Matrix Switch is replaced, all of the second tier and base 
UMT Matrix Switches should undergo a FUNC reset. 
−  Whenever a second tier UMT Matrix Switch is replaced, all of the base UMT Matrix 
Switches should undergo a FUNC reset. 
−  Whenever a base UMT Matrix Switch is replaced, only the new UMT Matrix Switch 
should undergo a FUNC reset. 
Figure 71 Redundant Configuration 