72  PARAGON II USER GUIDE  
Stacked Configurations 
Definition of stacking configuration: 
•  The P2-UMT Stacking Switch expands the number of available channel ports in a single 
switch. It does not add user ports. 
−  UMT Stacking Switch P2-UMT1664S has four 68-pin expansion ports. Two are input 
ports and two are output ports. The P2-UMT832S has only one 68-pin expansion input 
port and one output port. 
•  The P2-UMT1664M has two 68-pin expansion ports, and P2-UMT832M has one 68-pin 
expansion port. These represent input ports. 
•  One or more UMT Stacking switches connect to a P2-UMT Matrix Switch through stacking 
cables in a daisy chain connection – that is, the expansion port of a P2-UMT832M connects 
to the expansion output port of a P2-UMT832S, and the expansion input port of this P2-
UMT832S connects to the expansion output of another P2-UMT832S to form a daisy chain. 
•  For purposes here, this P2-UMT Matrix Switch is called the Master Device, and the UMT 
Stacking Switch is called the Stacking Device. 
•  The Master Device can be a base unit or a tiered unit. 
−  The stacking device that connects to a master device becomes an automatic extension of 
the master unit. 
System Constraints: 
•  The base unit should be a P2-UMT1664M / P2-UMT832M Matrix Switch 
•  The base unit must always be the latest release of P2-UMT Matrix Switch (hardware and 
firmware) in a closed configuration system. 
•  A Paragon I HW3 (with P2 firmware) can accommodate only one stacking switch. 
•  Up to three P2-UMT832S stacking units can be connected to each P2-UMT832M matrix unit. 
•  Only one P2-UMT1664S stacking units can be connected to each P2-1664M matrix unit. 
•  A maximum of 128 channel ports (Master Device + Stacking Devices) is permitted. When a 
P2-UMT1664M Matrix Switch acts as the Master Device, only one P2-UMT1664S Stacking 
Switch can be in daisy chain with it. When a P2-UMT832M Matrix Switch acts as the Master 
Device, up to three P2-UMT832S Stacking Switches can be in the daisy chain. 
•  A P2-UMT1664M can have only P2-UMT1664S Stacking Switches daisy chained to it. A 
P2-UMT832M can have only P2-UMT832S Stacking Switches daisy chained to it. You 
cannot mix unlike configurations of Master Devices and Stacking Switches. For example, 
you cannot use a P2-UMT832S Stacking Switch with a UMT1664 Master Device and vice-
versa. 
•  P2-UMT1664M / P2-UMT832M Matrix Switch and UMT1664/UMT832 hardware III Matrix 
Switch cannot act as Stacking Devices. 
Important: Do not power OFF an S Unit (Stacking Unit) when it is still connected to an 
M Unit (Main Unit). Keep the S Unit powered ON until it is disconnected from the M Unit. 