Before beginning the installation, create a plan as to the location of the air compressor and where you are
going to mount the compressed air outlets. On the plan locate outlets, tees, and elbows if needed.
AIR COMPRESSOR
Use a exible jumper hose from the air compressor to the lter regulator unit to reduce vibration to the
Maxline tubing.
FILTER REGULATOR
Maxline tubing is resistant to most common petroleum based compressor oils. Some new synthetic oils
will reduce the life of the tubing. A high quality lter regulator is recommended to catch oils
entering the air system.
PRESSURE RATINGS
The Maxline tubing is rated for 175 psi at 70 deg F
and less, 140 psi at a maximum
temperature of 140 deg F.
BENDING THE TUBING
The Maxline tubing can be bent
to hold any shape. Care should
be taken not to kink the tubing,
but rather bend the tubing in a
sweeping radius around corners
and obstacles. Elbow ttings are
available for sharp corners.
ASSEMBLY OF THREADED
COMPONENTS
Apply pipe sealant/paste to all
threaded connections, except
tting nuts during assembly.
TUBING INSTALLATION
Maxline tubing will expand and
contract slightly with changes in
temperature. Space tubing clips
every 3 ft for surface mount.
Always pressure test system
before closing up walls.
ax
LINE
In Wall Tubing Layout