5. Maintenance
Machine is equipped with advanced
warning detecon features. Please refer to
Troubleshoong Guide on following page. If
issue persists, contact an authorized service
centre for diagnosis before further use.
Never aempt to service machine other
than general maintenance procedures below.
Contact an authorized service centre if
issues arise.
Cleaning
Clean and check the machine on a
regular basis.
Remove wire coil and clean the feeding gear,
brake gear, and machine mouth areas aer
use to avoid dust and metal residue geng
into the machine and causing problems. This
can be done with an air blow gun.
Use air blow gun to also clean wire feeding
channel by ring air through wire feed pipe as
shown below.
1. Place the arm A unit in a 45˚ angle over
the rebar cross surface and push the
mouth towards the rebar.
2. Place arm A perpendicularly on top of the
rebar cross surface and with the mouth
centred over the cross.
Warning - Do not move the machine while
it is tying.
3. Cross-tying. Bend down the knot of the
rst e, before you make the second e.
Correct Usage
If issue found with wire feed or wire cung
mechanism, use air blow gun to clean wire
feeding channel by ring air through wire
feed channel as above.
Do not use oil based lubricants to clean
product as this may void warranty.
6. Storage
Machine must be kept at approx. 20˚C.
Do not store in cold condions, store under
warm and dry condions.
Keep out of reach of children.
Pipe