Installation Manual
Table Of Contents
10
No.
Normal
Operaon
Problem Warning Sound Cause What to Check Soluon
1
Power on -
The Tip Axis
is inialized
and the wire-
cuer operates
automacally.
No operaon
takes place.
No sound
emied.
Baery completely
empty.
Conrm the baery
is charged.
Perform normal charge.
Electrode plate has been
oxidized.
Take out the baery
and see if the
electrode is brown.
Polish terminal part of
the baery pack with
clean cloth, etc.
Connuous
short beeps.
Baery is empty.
Conrm the baery
is charged.
Perform normal charge.
One short beep. CONTACT AUTHORIZED SERVICE CENTRE
Twister cannot
go back to the
inial state.
Seven short
beeps repeated.
CONTACT AUTHORIZED SERVICE CENTRE
2
Trigger ON
- Wire sent out.
No wire is
sent out.
Two short beeps. Curl guide is open. Open/close curl guide. Fully close curl guide.
Three short
beeps repeated.
Tie wire has run out.
Check if the e wrie
has run out.
Set the new e wire.
Wire caught inside reel.
Check if wire inside
reel has been loosened
and caught.
Remove fray on reel.
Feeding channel is
blocked with foreign
substance.
Check the feeding channel.
Remove wire and use air
blow gun to clean wire
feeding channel by ring
air through wire feed pipe
(refer Cleaning Secon)
A small bump on e wire. Check e wire.
Cut o the part of the e
wire with the small bump.
3
Binding wire
draws a circle.
Curl is distorted
and steps out
of curl guide.
No sound
emied.
Wire, by hing
reinforcing bars,
was repelled.
Check if wire hits
reinforcing bars at binding.
Pay aenon so that wire
does not hit reinforcing
bars at binding.
7. Troubleshoong Guide