Installation Manual

10
No.
Normal
Operaon
Problem Warning Sound Cause What to Check Soluon
1
Power on -
The Tip Axis
is inialized
and the wire-
cuer operates
automacally.
No operaon
takes place.
No sound
emied.
Baery completely
empty.
Conrm the baery
is charged.
Perform normal charge.
Electrode plate has been
oxidized.
Take out the baery
and see if the
electrode is brown.
Polish terminal part of
the baery pack with
clean cloth, etc.
Connuous
short beeps.
Baery is empty.
Conrm the baery
is charged.
Perform normal charge.
One short beep. CONTACT AUTHORIZED SERVICE CENTRE
Twister cannot
go back to the
inial state.
Seven short
beeps repeated.
CONTACT AUTHORIZED SERVICE CENTRE
2
Trigger ON
- Wire sent out.
No wire is
sent out.
Two short beeps. Curl guide is open. Open/close curl guide. Fully close curl guide.
Three short
beeps repeated.
Tie wire has run out.
Check if the e wrie
has run out.
Set the new e wire.
Wire caught inside reel.
Check if wire inside
reel has been loosened
and caught.
Remove fray on reel.
Feeding channel is
blocked with foreign
substance.
Check the feeding channel.
Remove wire and use air
blow gun to clean wire
feeding channel by ring
air through wire feed pipe
(refer Cleaning Secon)
A small bump on e wire. Check e wire.
Cut o the part of the e
wire with the small bump.
3
Binding wire
draws a circle.
Curl is distorted
and steps out
of curl guide.
No sound
emied.
Wire, by hing
reinforcing bars,
was repelled.
Check if wire hits
reinforcing bars at binding.
Pay aenon so that wire
does not hit reinforcing
bars at binding.
7. Troubleshoong Guide