Specification

2
MORTAR MIX High-Strength Structural Repair Mortar
CURING: Water cure all Rapid Set
®
MORTAR MIX installations by keeping exposed surfaces
wet for a minimum of 1 hour. Begin curing as soon as the surface starts to lose its moist
sheen. When experiencing extended setting time due to cold temperature or the use of
retarder, longer curing times may be required. The objective of water curing shall be to
maintain a continuously wet surface until the product has achieved sufcient strength.
COLD WEATHER: Environmental and material temperatures below 70°F (21°C) may delay
setting time and reduce the rate of strength gain. Lower temperatures will have a more
pronounced effect. Thinner sections will be more signicantly affected. To compensate
for cold temperatures, keep material warm, use heated mix water, and follow ACI 306
Procedures for Cold Weather Concreting.
WARM WEATHER: Environmental and material temperatures above 70°F (21°C) may
speed setting time and increase the rate of strength gain. Higher temperatures will have
a more pronounced effect. To compensate for warm temperatures, keep material cool,
use chilled mix water, and follow ACI 305 Procedures for Hot Weather Concreting. The use
of Rapid Set
®
SET Control
®
retarding admixture from the Rapid Set
®
Concrete Pharmacy
will help offset the effects of high temperatures.
YIELD & PACKAGING: MORTAR MIX is available in 55-lb and 25-lb (25-kg and 11.3-kg)
sizes. One 55-lb (25-kg) bag of MORTAR MIX will yield approximately 0.5 ft
3
.
SHELF LIFE: MORTAR MIX has a shelf life of 12 months when stored properly in a dry
location, protected from moisture, out of direct sunlight, and in an undamaged package.
USER RESPONSIBILITY: Before using CTS products, read current technical data sheets,
bulletins, product labels and safety data sheets. It is the user’s responsibility to review
instructions and warnings for any CTS products prior to use.
WARNING: DO NOT BREATHE DUST. AVOID CONTACT WITH SKIN AND EYES. Use
material in well-ventilated areas only. Exposure to cement dust may irritate eyes, nose,
throat, and the upper respiratory system/lungs. Silica exposure by inhalation may result
in the development of lung injuries and pulmonary diseases, including silicosis and lung
cancer. Seek medical treatment if you experience difculty breathing while using this
product. The use of a NIOSH/MSHA-approved respirator (P-, N- or R-95) is recommended
to minimize inhalation of cement dust. Eat and drink only in dust-free areas to avoid
ingesting cement dust. Skin contact with dry material or wet mixtures may result in
bodily injury ranging from moderate irritation and thickening/cracking of skin to severe
skin damage from chemical burns. If irritation or burning occurs, seek medical treatment.
Protect eyes with goggles or safety glasses with side shields. Cover skin with protective
clothing. Use chemical resistant gloves and waterproof boots. In case of skin contact
with cement dust, immediately wash off dust with soap and water to avoid skin damage.
In case of skin contact with wet concrete, wash exposed skin areas with cold running
water as soon as possible. In case of eye contact with cement dust, ush immediately
and repeatedly with clean water, and consult a physician. If wet concrete splashes into
eyes, rinse eyes with clean water for at least 15 minutes and go to the hospital for
further treatment.
Please refer to the SDS and www.CTScement.com for additional safety information
regarding this material.
LIMITED WARRANTY: CTS CEMENT MANUFACTURING CORP. (CTS) warrants its materials
to be of good quality and, at its option, will replace or refund the purchase price of any
material proven to be defective within one (1) year from date of purchase. The above
remedies shall be the limit of CTS’s responsibility. Except for the foregoing, all warranties
expressed or implied, including merchantability and tness for a particular purpose, are
excluded. CTS shall not be liable for any consequential, incidental, or special damages
arising directly or indirectly from the use of the materials.
L WARNING
CANCER and REPRODUCTIVE HARM - www.P65Warnings.ca.gov
© 2017 CTS Cement Manufacturing Corp. DS_003_EN_120117T
CTS Cement Manufacturing Corp. | 12442 Knott St., Garden Grove, CA 92841 | 800-929-3030 | www.CTScement.com
USGBC and related logo is a trademark owned by the U.S. Green
Building Council and is used by permission.
Set Time, ASTM C266
Initial set 15 minutes
Final set 35 minutes
Compressive Strength, ASTM C109 Mod.**
1 hour* 2500 psi (17.2 MPa)
3 hours 4000 psi (27.6 MPa)
24 hours 5000 psi (34.5 MPa)
7 days 5500 psi (37.9 MPa)
28 days 6500 psi (44.8 MPa)
Slant Shear Bond Strength,
ASTM C882 Mod. per C928
24 hours 1200 psi (8.27 MPa)
28 days 2200 psi (15.2 MPa)
Splitting Tensile, ASTM C496 Mod.**
7 days 450 psi (3.10 MPa)
28 days 550 psi (3.79 MPa)
Flexural Strength, ASTM C348 Mod**
28 days 550 psi (3.79 MPa)
Freeze Thaw, C666
Durability factor 95%
Length Change,
ASTM C157 Mod. per C928 (max)
28 days in air -0.04
28 days in water 0.02
*After nal set
** Data obtained at ow consistency 100 by ASTM C1437
at 70°F (21°C)
TYPICAL PHYSICAL DATA