Operation Manual

en-31
8 MAINTENANCE & LUBRICATION
8.1 MAINTENANCE & LUBRICATION CHART _________________________________
MAINTENANCE AND LUBRICATION CHART
Interval Item Section
First 50 hours
Change P.T.O. gearbox Oil
Daily
10 hours
Check Hydraulic Fluid Level.
Clean Machine.
Weekly
Every 50 hours
Check for Loose Components.
Check for Hydraulic Leaks.
Check P.T.O. Gearbox Oil
Lubricate all Cutting Unit Grease Fittings.
Lubricate P.T.O.
Lubricate Control Valve Linkage.
End of season
Every 1000
hours
Change Hydraulic Oil & Filter.
Lubricate Cutting Unit Gearboxes.
Change P.T.O. gearbox Oil
Lubricate all Grease fittings weekly
A = Divertor Acctuator Rods, B =Cutting Unit Pivot, C = Cutting Unit Bearing Housing, (see
diagram)
FLUID REQUIREMENTS
Quantity Type
A Hydraulic Oil (with filter) 82 litres ISO VG 46
B P.T.O. Gearbox 0.52 litres Shell Spirax G90
C Cutting Unit Gearboxes - Shell Alvania HDX2
D General Lubrication -
Lithium Based General Purpose Grease
similar to Shell Darina R2
E Power Take Off Shaft - Rocol GP1 Grease