Instruction Manual
Air Line Heater / Filter Heater - Operation
Ransburg
LN-9811-14.1
11
1. Ensure that the rated line voltage and supply
voltage are the same:
115 VAC at 13 AMPS or
230 VAC at 6.5 AMPS
2. The lter heater system should be protected
by appropriate external fusing (115V-16 amp,
230V-8 amp).
3. Ensure that the power connector plug is secured
with a xing screw prior to operation.
4. Rotate the temperature control knob on the
side of the unit fully counterclockwise to the
‘minimum’ setting.
5.
Once the compressed air line has been turned on
and is owing, provide power to the lter heater
system by plugging the unit into rated outlet. Do
not exceed the maximum operating pressure
of 230 psi (16 bar).
6. Rotate the control knob clockwise to increase
the air temperature and counterclockwise to
decrease the temperature. The temperature
control knob should be altered gradually to allow
temperature stabilization to take place. Always
decrease the temperature to the minimum
temperature before unplugging unit.
The unit you have purchased is capable of
heating the ow of compressed air to 150°F
( 120°C) maximum. It is essential that all pip-
ing and equipment downstream is suitable for
this temperature. Maximum temperature tol-
erance of exible air hoses varies signicant-
ly, therefore, if in doubt, contact the supplier.
The unit must not be exposed to a con-
ducted electrical disturbance greater than a
frequency of 15MHz. The unit may show evi-
dence of a temperature decrease.
There are no serviceable components in the heater
assembly or its associated control electronics. If
a fault or damage occurs to the unit, replacement
spare parts are available.
NOTE
Start at miminum temperature set-
ting. Turn air on to the device, then turn
unit up to desired temperature. If you
see condensation on the applicator,
adjust the temperature knob to increase
the temperature.
OPERATION
C A U T I O N
!
The heater outlet port area and outlet
pipework will become hot when in use –
avoid personal contact.
Serious personal injury can result if these
instructions are not followed.
Do not attempt to remove any item on
the heater while it is under pressure.
Do not operate if there is a leak in the
lter heater system, immediately take unit
out of service and repair leak.
Do not operate above the maximum
working pressure 230 psig (16 bar) at maxi-
mum operating temperature 150°F (120°C).
Variable outlet temperature up to 150°F
(120°C) is dependent upon the inlet tem-
perature and air ow rate.
W A R N I N G
!
W A R N I N G
!
Heater is hot and should not be touched.