User Manual
TROUBLESHOOTING GUIDE (Cont.)
General Problem
Possible Causes
Corrective Action
No Fluid Flow
(Cont.)
Continuous Fluid
Flow
Uncontrollable Fluid
Flow
Fluid and/or Air
Leakage Between
the Valve Module
and Mounting Man-
ifold
Fluid Leakage
Around Fluid Valve
4. Clogged uid tube
5. Plugged bell cup
6. Worn bell cup splash plate
1. Flud valve open
2. Fluid valve seat damaged
or worn (MCV type)
1. Insufcient back pressure
to uid regulator
2. Fluid regulator does not
control ow
1. Fittings loose
2. O-ring is missing
3. O-ring is damaged
1. Damaged o-ring(s) on
outer diameter of valve
body (MCV style)
2. Damaged or worn needle
seals inside valve assem-
bly.
3. Dirt or debris in valve
4. Remove and inspect uid tube.
5. disassemble and clean.
6. Check splash plate for worn or missing teeth.
Replace.
1. a. Remove air pilot signal.
b. If still open, replace uid valve.
2. Replace uid valve seat.
1. Replace uid tube with the next smaller inner
diameter size.
2. Disassemble uid regulator and inspect for
failed components.
1. Tighten or replace.
2. Install o-ring.
3. Visually inspect for damage and replace.
1. Replace o-ring(s).
2. Replace valve assembly.
3. Remove debris. If damage to seat exists, re-
place valve and/or seat.
(Continued On Next Page)
Aerobell - Maintenance
62
LN-9264-08.2
Ransburg