User Manual

FIBER OPTIC REMOVAL/
REPLACEMENT
(77602 Valve Manifold Assembly)
To remove the ber optic sensor, grasp the ex-
posed end and turn counter-clockwise. Be careful
not to lose the o-ring on the opposite side.
To replace, insert into the cavity and turn clockwise
until it stops. The sensor should be ush on the
opposite side when correctly installed. Do not use
pliers to tighten, damage to sensor may occur,
hand tighten only.
Figure 37a: Fiber Optic Removal/ Replacement
Figure 37b: Fiber Optic Removal/ Replacement
VALVE MANIFOLD
ASSEMBLY/REMOVAL
(MCV STYLE)
When removing the quick-disconnect aomizer,
the valve manifold assembly may remain in the
mounting manifold. To remove, thread two (2)
8532-64C bolts into the threaded holes, 180° apart
from each other. Pull valve manifold straight out.
(5/16-18 threaded bolts or M8 X 1.25" bolts are
sufcient).
Figure 36: Valve Manifold Assembly/Removal
(MCV Style)
MOUNTING MANIFOLD
VALVE MANIFOLD
(MCV STYLE)
ALIGNMENT PIN AND GROOVE
8532-64C
VALVE MANIFOLD
REMOVAL BOLTS
FIER OPTIC TO BE FLUSH
WITH BACK SURFACE WHEN
FULL INSTALLED
79001-14
O-RING
77591-00
FIBER OPTIC SENSOR
TIGHTEN CLOCKWISE
TO INSTALL
79001-04
O-RING
VALE MANIFOLD
79001-14
O-RING
77591-00
FIBER OPTIC SENSOR
Aerobell - Maintenance
56
LN-9264-08.2
Ransburg