AdaptaFlow Node Adapter - Safety
44
44
4
AREAAREA
AREAAREA
AREA
Tells where hazards
may occur.
HAZARDHAZARD
HAZARDHAZARD
HAZARD
Tells what the hazard is.
SAFEGUARDSSAFEGUARDS
SAFEGUARDSSAFEGUARDS
SAFEGUARDS
Tells how to avoid the hazard.
Spray Area /Spray Area /
Spray Area /Spray Area /
Spray Area /
High VoltageHigh Voltage
High VoltageHigh Voltage
High Voltage
EquipmentEquipment
EquipmentEquipment
Equipment
This is a high voltage ungrounded
device that can produce electrical
arcs capable of igniting coating
materials.
Parts being sprayed must be supported on conveyors
or hangers and be grounded. The resistance between
the part and ground must not exceed 1 megohm.
(Reference NFPA-33)
A safe distance must be maintained between the
parts being coated and the atomizer bell. A distance
of at least 1 inch for each 10 kV of power supply output
voltage is required at all times.
Parts must be supported so that they will not swing
and reduce the clearance specified above.
All electrically conductive objects in the spray area,
with the exception of those objects required by the
process to be at high voltage, must be grounded.
Unless specifically approved for use in hazardous
locations, the power supply and other electrical
equipment must not be used in Class I, Division 1 or
2 locations.