The following basic troubleshooting can be performed by observing the Node Adapter front panel
displays. Also refer to the "Troubleshooting" section in the "AdaptaFlow 5000 Fluid Flow Control"
manual.
ActiveActive
ActiveActive
Active
LEDLED
LEDLED
LED
DescriptionDescription
DescriptionDescription
Description
Possible CausePossible Cause
Possible CausePossible Cause
Possible Cause
ON
OFF
BLINK
OFF
OFF
Normal operation
Node Adapter not communicating
Node Adapter is not controlling
I/O
Node Adapter processor is not
active
No Node Adapter activity
------
1. RIO cable not connected
2. Incorrect dipswitch settings on Node
Adapter for Baud rate, Address or
Starting Quarter
3. Problem with PLC
1. PLC in program mode
2. Another Node with same address on
RIO
1. Hardware failure
1. No power to Node Adapter
2. Hardware failure