Manual
LN-9217-00.2
AdaptaFlow Node Adapter - Operation
Normal Data BTR WordNormal Data BTR Word
Normal Data BTR WordNormal Data BTR Word
Normal Data BTR Word
ConfigurationConfiguration
ConfigurationConfiguration
Configuration
Word #Word #
Word #Word #
Word #
DescriptionDescription
DescriptionDescription
Description
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Configuration Word (0)
Channel No. (1-4)
Color No. (1-32)
Actual Flow Channel No. 1 (0-999 cc/min.)
Peak Flow Channel No. 1 (0-999 cc/min.)
Total Flow Channel No. 1 (0-32768 cc)
Analog Out Channel No. 1 (0-4095)
Actual Flow Channel No. 2 (0-999 cc/min.)
Peak Flow Channel No. 2 (0-999 cc/min.)
Total Flow Channel No. 2 (0-32768 cc)
Analog Out Channel No. 2 (0-4095)
Actual Flow Channel No. 3 (0-999 cc/min.)
Peak Flow Channel No. 3 (0-999 cc/min.)
Total Flow Channel No. 3 (0-32768 cc)
Analog Out Channel No. 3 (0-4095)
Actual Flow Channel No. 4 (0-999 cc/min.)
Peak Flow Channel No. 4 (0-999 cc/min.)
Total Flow Channel No. 4 (0-32768 cc)
Analog Out Channel No. 4 (0-4095)
Figure 13: Normal Data BTR Word ConfigurationFigure 13: Normal Data BTR Word Configuration
Figure 13: Normal Data BTR Word ConfigurationFigure 13: Normal Data BTR Word Configuration
Figure 13: Normal Data BTR Word Configuration
1919
1919
19
Global Data Block TGlobal Data Block T
Global Data Block TGlobal Data Block T
Global Data Block T
ransferransfer
ransferransfer
ransfer
Read Operational DescriptionsRead Operational Descriptions
Read Operational DescriptionsRead Operational Descriptions
Read Operational Descriptions
-Refer to Figure 14-Refer to Figure 14
-Refer to Figure 14-Refer to Figure 14
-Refer to Figure 14
The Global Block Transfer Read is identified by a
configuration word of two. This file is returned
immediately following a Global BTW instruction or
this data may also be requested by setting the
Normal BTW instructions configuration word to a
two.
Configuration WordConfiguration Word
Configuration WordConfiguration Word
Configuration Word
The configuration Word will equal a 2 to designate
that this BTR file represents Global Data.
The balance of the BTR words in this file are
described under the Global BTW section.
Actual FlowActual Flow
Actual FlowActual Flow
Actual Flow
This value is the real time flow rate for each
channel.
Peak FlowPeak Flow
Peak FlowPeak Flow
Peak Flow
This is current peak flow for each channel.
Total FlowTotal Flow
Total FlowTotal Flow
Total Flow
Value for total accumulated fluid delivered between
totalizer reset signals. This value can be zeroed
by a software command or by a hardware reset.
This can be used as a subtotal or intermediate total
to account for fluid delivered per job or shift, etc.
Analog OutAnalog Out
Analog OutAnalog Out
Analog Out
This is the current analog output value.