User Manual
CP-97-04.3
3838
3838
38
9040 Cascade Low Voltage Control Unit - Parts Identification
(Continued On Next Page)(Continued On Next Page)
(Continued On Next Page)(Continued On Next Page)
(Continued On Next Page)
1 PC Board and Heat Sink Assembly:
76892-01 For 76580-1XXXX, REA70 Applicator (72074)
76892-02 For 76580-2XXXX, REM Applicator (72364)
76892-04 For 76580-4XXXX, REM Automatic (73499)
76892-05 For 76580-5XXXX, REA9000 Automatic (75795), Robot (76110), and
76580-BXXXX, REA900 Automatic (77359)
76892-06 For 76580-6XXXX, REA90 Waterborne Applicator (75786)
76892-07 For 76580-7XXXX, REA90 Solventborne Applicator (75785) and
76580-AXXXXX, M90 Applicator (77073)
76892-08 For 76580-8XXXX, REA90 Solventborne Automatic (75787X-XXXX1)
76892-09 For 76580-9XXXX, REA90 Waterborne Automatic (75787X-XXXX2)
76892-16 For 78398-01, Single Bell, Domestic
76892-17 For 78398-02, Single Bell, Export
2 76434-01 ON./OFF Switch 1SW
3 70556-03 High Voltage Adjust Potentiometer 1POT
4 76436-91 Kilovolt (kV) Meter 1M
5 76436-92 Microamp (uA) 2M
6 72231-00 Low Voltage Cable Socket 3SOC
7 13742-01 Air Flow Switch Assembly: 1FS
13028-01 Housing
8012-00 Switch Assembly
6039-00 Piston
25766-106 Pressure Switch * 1PS, 2PS
8 75337-05 Power Supply, 18VDC 1SUP
9 LSME082-04 Fuse, PC Board, Slow Blow, 4 Amp (See Figure 5 for location.) F2
10 Fuse, Front Panel:
72771-06 Slow Blow, 1 Amp, 110-120 VAC Input 1FU
72771-01 Slow Blow, 0.5 Amp, 220-240 Input 1FU
11 76449-00 Detachable AC Line Cord
12 70539-00 Ground Wire Assembly
13 76455-01 LED Display Board
14 Overload Indicator and Reset Switch Assembly:
76442-01 Reset Switch (normally closed)
76441-00 Lens, Yellow
76443-01 Bulb
15 5627-00 Rubber Feet
16 Triple Setpoint/Analog Input Interface Board:
76031-05 For REA90 Solventborne Automatic
76031-06 For 76580-8XXXX, REA90 Waterborne Automatic
76031-07 Ror 76580-4XXXX, REM Automatic
76031-08 For REA9000 Automatic or Robot
76031-10 For 78398-01, Single Bell, Domestic
76892-11 For 78398-02, Single Bell, Export
76895-18 For 76580-BXXXX, REA900 Automatic
Item #Item #
Item #Item #
Item #
9040 CASCADE LOW VOL9040 CASCADE LOW VOL
9040 CASCADE LOW VOL9040 CASCADE LOW VOL
9040 CASCADE LOW VOL
TT
TT
T
AGE CONTROLAGE CONTROL
AGE CONTROLAGE CONTROL
AGE CONTROL
UNIT UNIT
UNIT UNIT
UNIT
- P - P
- P - P
- P
ARAR
ARAR
AR
TS LISTTS LIST
TS LISTTS LIST
TS LIST
(Figure 1(Figure 1
(Figure 1(Figure 1
(Figure 1
1)1)
1)1)
1)
Part #Part #
Part #Part #
Part #
DescriptionDescription
DescriptionDescription
Description
NotationNotation
NotationNotation
Notation
* Air flow switch used on 76580-1XXXX, -6XXXX, and -7XXXX.
Pressure switches used on 76580-4XXX, -5XXXX, -8XXXX, and -9XXXX.
ARCHIVE