Product Manual

14
SECTION 9
AIR SOURCE
This model requires a 14 to 15 CFM air source at 175
PSI maximum pressure. The safe operating pressure
range for this model is between 110 PSI and 175 PSI
at the machine. A 1/4” ID hose (or pipe) for connection
to the machine is satisfactory. Sufficient air pressure
assures good performance.
1. Connect the Air Supply to the Air Drier / Oiler. A proper
fitting (not included) to match the supply line of the air
supply connection is required. Use Teflon tape on the NPT
thread of the fitting. This connection is located on the right
side of the rear of the machine. (See Fig 9.1)
OILER ADJUSTMENT
1. Check Oil Level on Oil Level Gauge. (See Fig. 9.2)
If Oil level is low refer to Section 15, for filling instructions.
2. With the air source connected, depress the Bead
Breaker Pedal to operate the Bead Breaker.
3. Observe the sight glass and adjust the oil flow of the
oiler by turning the Oiler Adjustment Screw by using a small
screwdriver so that 2-3 drops of oil drip through the sight
glass for each operation of the Bead Breaker Pedal. (See
Fig 9.3)
SECTION 10
ELECTRICAL SOURCE
1. This unit requires power from a 15 amp electrical circuit.
The unit is supplied standard with a 110 Volt power cord
and plug. (See Fig 10.1). Please remember that ALL F
models are standard 220 V only.
2. Refer to the serial tag of the machine for specific
electrical requirements. Have a licensed electrical techni-
cian perform any necessary changes to the power source
and power cord before plugging in the unit. The electrical
source must have a solid connection between ground and
building ground.
FAILURE TO PROPERLY MAINTAIN PROPER OIL
LEVEL AND ADJUST THE OIL FLOW MAY VOID THE
WARRANTY AND DAMAGE THE BEAD BREAKER
CYLINDER AND OTHER AIR COMPONENTS.
NOTE:
THIS ADJUSTMENT WILL REQUIRE AT LEAST TWO
OPERATORS TO PERFORM.
Fig 10.1
Fig 9.1
Fig 9.2