User's Manual

SDRe Programming Software
Revision V1.0
P a g e | 63
4.6.2.9. Enable the Call Length control on Digital Profiles
If you want Set a limit of minutes for a call length, then fill this field.
0 minute means no limit. Absolute Max call length is 255 minutes.
Figure 76: Repeater MAX Call Length on Digital Profiles
To store the value, click on any part of the tab. To save the value,
press [Ok] or Cancel if you want to discard the changes.
4.6.2.10. Repeater Penalty setup on Digital Profiles
If Call length limit is reached, the repeater may apply a penalty for
the digital ID who reached the limit.
For example, if a particular group, who uses the channel, reaches
the max length accepted for this profile, that group remains inactive
by the amount of seconds defined on this step.
Max penalty length is 255 seconds.
0 seconds of penalty means no penalty, so the group can setup a
new call immediately.
Figure 77: Penalty for traffic control on Analog Profiles
To store the value, click on any part of the tab. To save the value,
press [Ok] or Cancel if you want to discard the changes.
4.6.2.11. Release time for time-out timer reset for Digital Profiles
If Call length limit is active (Call Length timer not equal to 0), the
repeater may apply a penalty for the group who has reached the
limit.