User's Manual

SDRe Programming Software
Revision V1.0
P a g e | 56
Max penalty length is 255 seconds.
0 seconds of penalty means no penalty, so the group can setup a
new call immediately.
Figure 62: Penalty for traffic control on Analog Profiles
To store the value, click on any part of the tab. To save the value,
press [Ok] or Cancel if you want to discard the changes.
4.6.1.10. Release time for time-out timer reset
If call length limit is active (Call Length timer not equal to 0), the
repeater may apply a penalty for the CTCSS tone who reached the
limit.
This parameter specifies the time without any activity of that group
to reset the time out timer, which controls the max call length.
To setup this value, please fill the field.
Figure 63: Release time for Traffic Control on Analog Profiles
Max Release time length is 255 seconds.
0 seconds of release means instant reset of the call length timer.
To store the value, click on any part of the tab. To save the value,
press [Ok] or Cancel if you want to discard the changes.
4.6.1.11. Voice inversion encryption setup
ST-9116 supports voice inversion encryption for analog profiles. If
you want to enable it, please check the [Enabled] box then input the
right voice inversion sub-carrier for this profile.