User's Manual
SDRe Programming Software
Revision V1.0
P a g e | 34
4.3.1.3. FAN Mode:
The operating temperature of the repeater may not exceed 100°C
[212°F]. Depending on environmental conditions, the internal
FAN will help the heat-sync to keep temperature under the limit,
extending the repeater performance.
Press on the arrow to list down the possible values:
Figure 25: FAN Setting
Auto: The FAN will work controlled by repeater temperature
limits programed on the alignment procedure (See ST-9116
Service manual – Alignment).
On: The FAN will remains all time on. This option will demand
more quiescent current than required becoming inefficient. It
should be useful for high temperature environments.
Off: The FAN never will blow.
4.3.1.4. Set Low Power on Voltage:
If the DC power voltage drops under the limit programmed on this
field, then the repeater will jump to the low RF power programed for
the repeater to save battery. This feature is especially useful for
solar-powered sites or when the site works on power back up during
a possible AC failure.
Figure 26: Low power on low voltage setting