User guide
INSTALLATION
Check the appliance is electrically safe when you have nished.
23
Electrical Connection
The cooker must be installed by a qualied electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
WARNING: THIS APPLIANCE MUST BE EARTHED.
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
The cooker MUST not be connected to an ordinary
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (Fig. 7.8 and Fig. 7.9). Check that the links are correctly
tted and that the terminal screws are tight.
Final Checks
Hob Check
Check each cooking zone in turn. Be sure to use pans of the
correct size and material.
Oven Check
Set the clock as described earlier in the instructions, and then
turn on the ovens. Check that the oven fans start to turn and
that the ovens start to heat up.
Final Fitting
Fitting the Plinth
Loosen the 3 screws along the front bottom edge of the
cooker. Hook the central keyhole over the central screw. Twist
and t each end keyhole over their respective screws. Tighten
the xing screws (Fig. 7.10).
Customer Care
Installer: Please complete your details in this guide, inform
the user how to operate the cooker and hand over the
instructions.
Thank you.
ArtNo.130-0010 Electrical connections single-phase
L
N
230 V ac 50 Hz
10 mm² max
6 mm² max
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we recommend
that the cooker is protected on an individual RCD (Residual
Current Device) or RCBO (Residual Current Breaker with
Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
L1
N
L3
L2
3N ac
230/400 V 50 Hz
6 mm² max
10 mm² max
6 mm² max
ArtNo.000-0006 - Securing the 110 plinth
Fig. 7.8
Fig. 7.9
Fig. 7.10