SR 2 SMART REMOTE CONTENTS Quick Start Front Panel Description Rear Panel Description Working with Smart Remotes SR 2 Wiring Guidelines SR 2 Communication Protocol Smart Remote Specifications Factory Authorized Service Limited Domestic Warranty Warranty Procedure in USA Declaration of Conformity 2 3 4 5 10 18 28 30 30 32 34 FCC Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
SR 2 SMART REMOTE OPERATORS MANUAL Quick Start Who would guess that a little box with one knob could have such a thick manual? At least read this section for the basics. Architectural look. Since Decora plates come in different colors, each SR 2 is shipped with 4 different color inserts for installation behind the lens (we ship them without an insert installed).
Front Panel Description 1 1 Colored insert (4 colors included). 2 Clear lens helps support different color templates which mount behind the lens. 3 LED indicators. Indicate the current “level” of the linked parameter(s). 4 Encoder Knob with momentary push switch is the user input to the SR 2.
MADE IN U.S.A. ACN.001.345.482 RANE CORP. ENCODER LOCK REMOTE INTERFACE PORT A SR 2 6 7 5 2 3 ADDRESS 1 1 0 4 B +V -V Rear Panel Description 2 1 6-wire Euroblock connector. Connects the SR 2 to a controller. A connects to RS-485 data +, B connects to RS-485 data –. +V is the positive side of the power supply rail. –V is the negative/ground side of the power supply rail. Ground is the connection point for the shield when shielded cable is used.
Working with Smart Remotes Smart Remote Overview Smart Remotes are configured within Drag Net 4 and higher. The following sections describe configuring the various parameters and modes for the remotes themselves. Details on assigning remotes to control parameters and functions with an RPM are found in Drag Net’s included Help file (Help > Help Topics). Creating a new Configuration Smart Remote configurations can be created as offline Storage files, for subsequent transfer to a Live remote.
SR 2 Configuration Parameters The SR 2 features a 31-position LED indicator and rotary data encoder with integrated push switch. The push switch permits control of two independent parameters: Level 1 when the encoder is rotated normally, and Level 2 when the encoder is pushed and held while rotating. Each SR 2 ships with four faceplate inserts: white (w/black logo), white (w/almond logo), almond (w/black logo) and black (w/white logo).
Baud Rate The Baud Rate can only be set when Serial Mode is selected during polling. When configuring Remotes used with Rane controllers (i.e., RPM 88/44/22), the RW 485 baud rate of 38400 bps is automatically set. Should you encounter communication problems, settings can be restored to 38400 baud, 10 ms delay by holding the encoder in while powering the remote. Release the encoder when its LED lights.
Live to Storage Important: Transferring from a Live remote to an existing Storage configuration overwrites the Storage configuration. To transfer from a Live remote to a Storage configuration: 1. Toggle the Project Window on if it’s not already visible (View > Project). 2a. Drag and drop the Live remote onto an existing destination Storage configuration. - or 2b.
Updating Smart Remote Firmware It may be necessary to update a Smart Remote’s firmware in order to add features or address one of those pesky glitches that only seem to appear after the product’s been released. Remotes with the following firmware versions can be upgraded as new firmware becomes available: Remote With Firmware Version SR 2 2.0 and higher SR 3 4.0 and higher SR 4 1.0 and higher Older remotes may not be updateable, or updateable only by Rane.
SR 2 Wiring Guidelines Restrictions 24 AWG CAT 5 cable resistance = 26 ohms per 1,000 feet. There are two wiring restrictions. First, RW 485 has a maximum of 1,000 feet. The total length may not exceed this limit in any combination of series or parallel runs. Second, the voltage of the power supply also affects the maximum distance of each length between, and the number of Remotes.
12 to 15 VDC regulated power supply: Radio Shack 273-1691 or equivalent. Radio Shack 273-1641 Adaptaplug TIP RPM 88 REMOTE INTERFACE PORT (RW 485) A B +V -V To more SR Remotes White stripe = (+) A B +V -V ENCODER LOCK REMOTE INTERFACE PORT ADDRESS SR 7 4 5 6 1 3 0 ACN 001 345 482 MADE IN U.S.A. RANE CORP.
Cable Type 1 2 twisted pair unshielded CAT 5, Belden #1588(A,R) 2 twisted pair unshielded CAT 5, Belden #1590A REGULATED POWER SUPPLY Single Run Distance (Series) d1 d2 d3 RPM REMOTE INTERFACE PORT (RW 485) A dT B +V -V Single run restriction: Total cable length d1+d2+d3 = dT ≤921 ft (per table example) Multiple Run Distances (Star) REGULATED POWER SUPPLY d1 d2 RPM REMOTE INTERFACE PORT (RW 485) A B +V -V d3 Manual-12
Cable Type 1 2 twisted pair unshielded CAT 5, Belden #1588(A,R) 2 twisted pair unshielded CAT 5, Belden #1590A Vs = 15V RPM 44 RPM 22 Vs = 12V RPM 88 Requires external supply Vs = 8V Max Distance for Cable (feet) 1000 1000 921 722 594 504 438 388 Max Distance for Cable (meters) 305 305 281 220 181 154 134 118 Number of SR 2 Remotes 1 2 3 4 5 6 7 8 1000 795 576 451 371 315 274 242 305 242 176 138 113 96 84 74 1 2 3 4 5 6 7 8 256 159 115 90 74 63 55 48 78 48 35 28 23 19 17 15 1 2 3 4 5 6 7 8 Not
Cable Type 1 Multiple run restriction (per table entries): d1 ≤921 ft, d2 ≤1,000 ft, d3 ≤1,000 ft Total cable length must be under 1,000 ft: d1 + d2 + d3 = dT ≤1,000 ft RPM Examples: So if d1=400 ft (<921 ft, OK) d2=300 ft (<1,000 ft, OK) d3=200 ft (<1,000 ft, OK) d1+d2+d3=900 ft, then it's all OK! REMOTE INTERFACE PORT (RW 485) ORANGE WHITE/ORANGE but if d1=400 ft (<921 ft, OK) d2=500 ft (<1,000 ft, OK) d3=300 ft (<1,000 ft, OK) d1+d2+d3=1,200 ft, then it's NOT OK! BELDEN #1588 (A,R) BELDEN #1590 (
Cable Type 2 4 twisted pair unshielded CAT 5, Belden #1583(A, B, E, ENH, R) 4 twisted pair shielded CAT 5, Belden #1624 (P, R) 4 twisted pair unsheilded CAT 5, Belden #1700 (A, R) REGULATED POWER SUPPLY Single Run Distance (Series) d1 d2 d3 RPM REMOTE INTERFACE PORT (RW 485) A dT B +V -V Single run restriction: Total cable length d1+d2+d3 = dT ≤1,000 ft (per table example) Multiple Run Distances (Star) REGULATED POWER SUPPLY d1 d2 RPM REMOTE INTERFACE PORT (RW 485) A B +V -V d3 Manual-15
Cable Type 2 4 twisted pair unshielded CAT 5, Belden #1583(A, B, E, ENH, R) 4 twisted pair shielded CAT 5, Belden #1624 (P, R) 4 twisted pair unsheilded CAT 5, Belden #1700 (A, R) Vs = 15V RPM 44 RPM 22 Vs = 12V RPM 88 Requires external supply Vs = 8V Max Distance for Cable (feet) 1000 1000 1000 1000 1000 1000 1000 1000 Max Distance for Cable (meters) 305 305 305 305 305 305 305 305 Number of SR 2 Remotes 1 2 3 4 5 6 7 8 1000 1000 1000 1000 1000 946 822 727 305 305 305 305 305 288 251 222 1 2 3 4
Cable Type 2 More conductors mean greater operating distance. Multiple run restriction (per table entries): d1 ≤1,000 ft, d2 ≤1,000 ft, d3 ≤1,000 ft Total cable length must be under 1,000 ft: d1 + d2 + d3 = dT ≤1,000 ft RPM REMOTE INTERFACE PORT (RW 485) B +V -V but if d1=500 ft (<1,000 ft, OK) d2=400 ft (<1,000 ft, OK) d3=300 ft (<1,000 ft, OK) d1+d2+d3=1,200 ft, then it's NOT OK! B +V -V E NCOD E R LOC K ADD R ES S 5 6 4 1 1 1 3 ADDRESS 7 5 4 SR MADE IN U.S.A . RA NE CO R P.
SR 2 Communication Protocol The SR 2 communication protocol follows Rane’s RW 485 specification. The following describes the SR 2 implementation. Physical The baud rate is 38,400 bps with No parity, 8 Data Bits, 1 Stop Bit (N81) format. The SR 2 also supports 9600, 19200, 57600, and 115200 bps. When configuring Remotes used with Rane controllers (RPM 22, 44, 88), the RW 485 baud rate of 38400 bps is required. At the end of a command message, the Master must release the bus within 10 ms.
The msgtype is a one byte set of flags indicating options, bit 7=MSB: bit 0) set = checksum is valid bit 1) set = there has been an error (response only) bit 2-5) reserved, cleared to 0 bit 6) always 1 bit 7) always 0 If the controller wants the SR 2 to verify the checksum, it would send a value of $41, or an ASCII ‘A’. If the controller wants the SR 2 to ignore the checksum, it would send a value of $40, or an ASCII ‘@’. The SR 2 echoes back the it was sent.
The SR 2 responds with response data based on the commands/arguments it was sent. The SR 2 limits its response data to 40 characters. In the case of an error, the response data is: n,"ERROR" where n is an error code defined below: Hex ASCII Error Code Meaning $31 '1' Sent invalid. $32 '2' Sent did not verify. $33 '3' Sent parse error. $34 '4' Sent greater than 40 characters, or the number of concatenated commands >4.
Configuration Commands V Get Firmware, Hardware Version Send: V Response: n1,n2,"OK" Where: n1 is a two digit ASCII encoded decimal value representation of the firmware version. The first digit is the major firmware version and the second digit is the minor firmware version. n2 is a one digit ASCII encoded decimal value representation of the hardware version. Example: 13,2,"OK" means firmware version 1.3, hardware version 2.
To write a stored parameter value: Send: SPL,n1,n2 Where: n1 is the stored parameter index. n2 is the value to be stored. Example: SPL,1,0 sets Auto Level parameter to 0, disabling the Auto Level function. Response: "OK" Encoder Input Commands ILD Read/Write LED Enable byte Reads or writes the LED Enable byte.
To write the Software Input Lock status: Send: ILK,n1 Where: n1 is the Software Input Lock byte. The lock byte range is [0, 7]. Example: ILK,2 locks the second level. Response: "OK" IQ Input Query Returns the current main level and second level. Resets the command state to No Operation. Send: IQ Response: n1,n2,"OK" Where: n1 is the current main level. The main level range is [1, 31]. n2 is the current second level. The second level range is [1, 31].
IS Input Suggest Suggests new main level and second level. Resets the command state to No Operation. If Auto Level is enabled, the main level is updated and indicated by the LED only if the device’s main level has not changed by someone turning the encoder. Otherwise, if Auto Level is disabled, the main level is updated and indicated by the LED regardless of encoder input.
ISR Input Suggest Raw Same operation as IS Input Suggest except ISR returns the command state byte and button time. Suggests new main level and second level. Resets the command state to No Operation. If Auto Level is enabled, the main level is updated and indicated by the LED only if the device’s main level has not changed by someone turning the encoder. Otherwise, if Auto Level is disabled, the main level is updated and indicated by the LED regardless of encoder input.
IF Input Force Forces new main level and second level. Resets the command state to No Operation. The main level is updated and indicated by the LED regardless of Auto Level configuration. If Auto Second Level is enabled, the second level is updated and indicated by the flashing LED. Otherwise, if Auto Second Level is disabled, the second level is updated. Send: IF,n1,n2 Where: n1 is the new main level. The main level range is [0, 31]. If n1 is zero, the main level remains unchanged.
Stored Parameter List (SPL) Below is a table of stored parameters followed by descriptions of each parameter. Index Description Values Setting Meaning 1 Auto Level 0-1 1 disabled - enabled 2 Auto Second Level 0-1 1 disabled - enabled 3 Auto Lock 0-1 1 disabled - enabled 4 Baud Rate 0-4 2 0 = 9600, 1 = 19200, 2 = 38400, 3 = 57600, 4 = 115200 5 RW 485 Transmit Delay (ms) 2 - 200 10 2 - 200 ms Parameter Descriptions 1.
Smart Remote Specifications Parameter I/O: Type ..........Impedance ..........Baud Rate ..........Data Format Power Supply Requirement RW 485 Drive Current SR 4: Supply Current SR 3: Supply Current SR 2: Supply Current All Units: Agency Listing ..........Construction SR 2 / SR 4: Size SR 3: Size All Units: Weight .....Shipping: Size ..........Weight Manual-28 Specification RS-485 12k 38400 9600 19200 57600 115200 N81 7 minimum, 16 maximum 28 52 50 95 42 CE (EMC) CE (safety) Exempt Steel Polycarbonate 4.
Limit Units min <1% <1% <1% <1% <1% Ω bps bps bps bps bps min +1 +5 +5 +5 +4 VDC mA mA mA mA mA Conditions/Comments Euroblock connector Receive Mode RW 485 baud rate Programmable Programmable Programmable Programmable No parity, 8 data bits, 1 stop bit DC voltage @ +V referenced to -V No termination, communication active. One remote per bus active at a time.
Warranty Factory Authorized Service Your unit may be serviced by the Rane Factory or any Authorized Rane Service Center. To find a Service Center near you, please call the Rane factory, or check the Rane website. Please do not return your unit to Rane without prior authorization. Rane Corporation To obtain service or a Return Authorization, please phone 425-355-6000 or Fax 425-347-7757 The current list of U.S. Rane Authorized Service Centers is on our website: www.rane.com/service.
LIMITED WARRANTY OUTSIDE THE U.S.A. RANE PRODUCTS ARE WARRANTED ONLY IN THE COUNTRY WHERE PURCHASED, THROUGH THE AUTHORIZED RANE DISTRIBUTOR IN THAT COUNTRY, AGAINST DEFECTS IN MATERIAL OR WORKMANSHIP, THE SPECIFIC PERIOD OF THIS LIMITED WARRANTY SHALL BE THAT WHICH IS DESCRIBED TO THE ORIGINAL RETAIL PURCHASER BY THE AUTHORIZED RANE DEALER OR DISTRIBUTOR AT THE TIME OF PURCHASE.
Warranty Procedure - Valid in USA only NOTICE! You must complete and return the warranty card or register your product online to extend the Warranty from 2 years to 3 years! TO VALIDATE YOUR EXTENDED WARRANTY Use the postcard that came in the box with your unit, or go to www.rane.com and click on New Product Registration. Fill out the warranty completely, being sure to include the model and serial number of the unit since this is how warranties are tracked. If your Rane product was purchased in the U.S.A.
FACTORY SERVICE If you wish your Rane product to be serviced at the factory, it must be shipped fully insured, in the original packing box or equivalent. This warranty will not cover repairs on products damaged through improper packaging. If possible, avoid sending products through the U.S. mail. Be sure to include in the package: 1. Complete return street shipping address (P.O. Box numbers are not acceptable). 2.
Manual-34 EN60065:1998 EN55103-1:1996 EN55103-2:1996 ENVIRONMENT E2 COMMERCIAL AND LIGHT INDUSTRIAL Standard(s) to which conformity is declared: This equipment has been tested and found to be in compliance with all applicable standards and regulations applying to the EU’s Low Voltage (LV) directive 73/23/EEC, and Electromagnetic Compatibility (EMC) directive 89/336/EEC.
(Signature) Mukilteo WA USA (Place) (Date) (Position) (Full Name) November1, 2001 Compliance Engineer Roy G. Gill I, the undersigned, hereby declare that the equipment specified above conforms to the Directive(s) and Standard(s) shown above. No susceptibilities observed.
1.4" 5 6 7 ADDRESS 2 3 1.95" 1 Rane part 14332 MADE IN U.S.A. ACN.001.345.482 RANE CORP. SR 2 ENCODER LOCK B +V -V REMOTE INTERFACE PORT A 1.7" 4 4.1" 3.8" 3.25" SR 2 SMART REMOTE 0.15" 0.