Specifications

Manual-1
MA 4
MULTICHANNEL AMPLIFIER
DIGITAL
AMPLIFIER
dB Headroom dB Headroom dB Headroom dB Headroom
3
6
12
24
Limit
1
Comp
Exp
Fault
Load
Ready
3
6
12
24
Limit
2
Comp
Exp
Fault
Load
Ready
3
6
12
24
Limit
3
Comp
Exp
Fault
Load
Ready
3
6
12
24
Limit
4
ON
Comp
Exp
Fault
Load
Ready
MA 4
OPERATORS MANUAL
Quick Start
Basic MA 4 operation is straightforward:
1. e universal switching power supply works with 100 to 240 VAC, 50/60 Hz.
2. Make sure the front panel power switch is o (the unit consumes 5 watts in standby mode).
3. Connect balanced inputs (rear panel).
4. Set SENSITIVITY controls to +22 (see why on page Manual-2) (rear panel).
5. Turn the Downward EXPander ON (rear panel).
6. Set COMPressor to 10 dB (rear panel).
7. Select the appropriate HIGH PASS lter frequency (20, 40, 60 or 80 Hz on rear panel).
8. Connect speaker loads (rear panel).
9. Make sure you have adequate ventilation around the unit – see Safety Instructions.
10. Turn ON the front panel power switch. Youre good to go!
Metering shows the status of the amplier at a glance (see page Manual-3). Headroom (with any load), dynamics control, Fault status
and Load status are indicated for each channel.
Extra Credit
For remote turn-on, fault reporting and back-up amplier operations, and remote level control wiring, see page Manual-4.
For FAULT FLAG operation (applications and reported faults), see page Manual-3.
MA 4
100-240V
50/60 Hz 500 WATTS
MADE IN U.S.A.
RANE CORP.
Class 2 Wiring
OUTPUTS
Active Low Use Rane VR 2 or 20 kΩ pot
HIGH-PASS
20Hz
40Hz
60Hz
80Hz
ON
4
+
+
+
+
+
+
+
+
REMOTE LEVEL 4
4FLAG 3 2 1
FAULT
Vr
Vc
Vc
Vc
Vr
Vc
+
+
+
+
+
+
+
+
3
2
1
MASTER
SLAVE
COMP
4
3
2
1
1
2
3
4
+
+
+
+
Vr
Vc
Vc
Vc
Vr
Vc
+
+
+
+
INPUTSMODE
13
22
dBu
SENSITIVITY
4
3
13
22
dBu
SENSITIVITY
4
2
13
22
dBu
SENSITIVITY
4
1
13
22
dBu
SENSITIVITY
4
EXP ON
3
INT EXT
LOAD
2
INT EXT
LOAD
1
INT EXT
LOAD
4
INT EXT
LOAD
COMMERCIAL AUDIO
EQUIPMENT 24TJ
R
4321
ON
4321
ON
+
+
+
+
SOURCE 4
SOURCE 3
SOURCE 2
SOURCE 1
WEAR PARTS: This product contains no wear parts.
Installation
• No rear mounting hardware required.
• Allow adequate ventilation to keep ambient temperature around the amplier below 104˚F (40˚C).
• Fan cooled with inset intake on left side and inset exhaust on right side (no lter)
• Amplier heat load in Btu/hr at 100/240 VAC
º 10.2 / 13.3 Btu/hr All ampliers in standby
º 112.3 / 95.5 Btu/hr All ampliers on, no signal
º 167 / 139 Btu/hr All ampliers driven, pink noise, 12 watts avg. 4:1 crest
º Note: 1 watt x 3.413 = 1 Btu/hr.