ASSEMBLY / DISASSEMBLY
5.20 Remote Reading Thermometer
P/N 141055 Remote Reading Thermometer
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. Remove the left and right side panels.
3. On the left side, remove the 5/8 compression hex nut
holding the capillary bulb in place.
4. Push the capillary bulb out from the inside of the cavity.
5. Disconnect capillary tube from cable support bracket.
6. With a small flat blade screw driver, remove the (3) pan
head 6-32 x 3/8” long screw that holds the face or the
thermometer to the front panel.
7. Pull the gauge and capillary out through the hole in the
front panel.
Installation
8. Pass the bulb, capillary and gauge through the opening in
the front panel.
9. Fasten the gauge to the front panel with the (3) pan head
6-32 x 3/8” long screw that holds the face of the
thermometer to the front panel.
10. Re-connect capillary to cable support bracket.
11. Tighten the compression nut to the bulb fitting.
12. Connect power and test operation, especially for leaks
around the capillary bulb.
5.21 Water Level Float
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. Remove the right side cover from the steamer.
3. Disconnect the water level floats from the relay board.
4. Loosen and remove the hex locking nut and washer.
5. Remove the water level floats from inside the cavity.
Installation
6. Insert the new water level floats through the opening from
inside the steamer cavity (be sure the o-ring seal is in place).
The lower float should pivot upward and the upper float
should pivot downward.
7. From the back, put on the washer and locking nut and
tighten to prevent any water leaks.
8. Attach the float wires to relay board.
9. Turn on the branch circuit power supply.
10. Turn on the steamer and test.