Specifications

9
A. Controls
Operator controls are on the front right of the unit.
The SmartSteam Boilerless Steamer control panel
has the following touch pads and indicator lights:
The ON/OFF touch pad gets the SmartSteam
Boilerless Steamer ready for use and also
shuts it OFF.
The READY indicator light shows that the
steam generating reservoir is at standby
temperature and the cavity is hot enough to
begin steaming.
The Upper/Red SERVICE indicator light and
Door/Lid light indicate the water level probes
have stopped working and need to be
cleaned.
The Door/Lid Indicator light illuminates when
the door is not properly closed.
The HI TEMP indicator light comes on when
the unit is too hot.
      and
      
      

The TIMING indicator light stays on when
the timer is running.
The Lower/White SERVICE indicator light
shows when the control cooling fan may not
be functioning properly. The light may come
on for several minutes during normal
operation. If it stays on for more than 30
minutes, call for service. It is okay to use
steamer until service arrives, but continued
use for prolonged periods could result in
component damage due to excessive
temperatures.
The hour meter records the cumulative
hours the steamer has been used. Refer to
warranty statement.
OM-SSB-3G/5G/10GF
Operation
WARNING
ANY POTENTIAL USER OF THE EQUIPMENT MUST BE TRAINED IN SAFE AND CORRECT OPERATING
PROCEDURES.
P/N 149398 REV B
Dial OFF Position



HI TEMP
Indicator
COOLING FAN


TIMED


DOOR OPEN

Control
Power
ON/OFF


HOUR Meter