Specifications

8
OM-SSB-3G/5G/10GF
Initial Startup
After the SmartSteam Boilerless Steamer has been
installed, test it to ensure that the unit is operating
correctly.
1. Remove all literature and packing materials
from the interior and exterior of the unit.
2. Make sure the water supply line is open.
3. Make sure that the gas supply line is open
and that the manual knob on the main gas
valve is turned to the ON position. This
valve is located behind the front access
panel on the right side of the unit.
4. Turn on electrical service to the unit. The
steamer will not operate without electrical
power. Do not attempt to operate the unit
during a power failure.
NOTE: The door MUST be closed for the
main burner to work.
5. To turn unit on, toggle the lower rocker
switch to the ON position and press the ON/OFF
button on the upper control panel.
NOTE: For normal day to day operation, the
rocker switch may be left in the ON position.
Use the upper control panel ON/OFF button to
turn unit ON and OFF.
 When the steam generating reservoir
has lled with water, the main burners will
ignite automatically. Within 15 minutes or
less the READY light will come on, indicting
that the water has reached its standby
temperature. When the READY light is
displayed, you may take any one of the
following steps;
a. Set the timer to the desired timed
steaming.
b. Turn the timer knob to the manual ON
position for continuous steam.
c. Let the unit stay at ready condition.
WARNING
WHEN YOU OPEN THE DOOR, STAY AWAY
FROM STEAM COMING OUT OF THE UNIT.
STEAM CAN CAUSE BURNS.
7. To shut down the unit, press the ON/OFF touch
pad. The steam generating reservoir will then
drain.
. If the steamer behaves as described, the
unit is functining correctly and ready for USE.
NOTE:

