Unit Installation (cont)
Cross ventilation in the cabinet is recommended to maintain
ambient temperature 86°F or less. Avoid surrounding your drop in
with other heat generating equipment and keep out of direct
sunlight. Also, avoid locating in an unheated room or where the
room temperature may drop below 55° F or above 86°F . It is
recommended that drop in be installed with the condenser coil
facing a ventilated opening in the cabinet.
INSTALLATION CHECKLIST
After the final location has been determined, refer to the following checklist prior to
start-up:
1. Follow cut out dimensions provided for specific models to properly size
the opening for your drop in.
NOTE: It is recommended that drop in be installed with the condenser
coil facing a ventilated opening in the cabinet
2. Check cord and plug of unit to assure no damage has occurred to
these components.
3. Assure all refrigeration lines are clear of obstruction before, during, and
after being installed into the counter.
4. Check all sheet metal surrounding the mechanical compartment to
assure no damage has occurred in these areas.
5. Plug in unit and turn on main on/off power switch.
6. Allow unit time to cool down to temperature. A layer of frost will form
and remain around the inside perimeter of the rail.
7. Refer to the front of this manual for serial number location. Please
record this information in your manual on page 3 now. It will be
necessary when ordering replacement parts or requesting warranty
service.
8. Confirm that the unit is holding temperature. Set control to desired
temperature for your particular ambient and altitude.