7. Servicing the condenser fan.
Inspect the condenser fan motor by removing the mechanical housing cover to gain access.
Unplug the unit. Clean the fan blade, and turn it to see if the blade rotates freely. If
the motor binds, replace it. If the blade is damaged, unscrew the nut that holds it to
the motor shaft and pull it off. Install a new fan blade, replacing any washers, and
tighten the nut.
To test the condenser fan motor disconnect
the wires to the fan motor. Set a multimeter at
RX10 and touch one probe to each terminal. The
multimeter needle should show approximately 45 to
50 ohms resistance; a lower reading means the
motor is faulty. Next set the meter at RX1000 and
touch one probe to the motor terminals and the
other one to any unpainted metal part of the unit.
If the meter needle moves, the motor is grounded
and should be replaced. To remove the motor
unscrew the bracket that holds the fan motor to
its housing, slide the motor out of the housing.
Remove the fan blade from the old motor and attach
it to the new motor, replacing any washers.
Install the new motor in its housing by screwing
the bracket in place. Reattach the wires to the
motor terminals.
8. Servicing the compressor.
The compressor is part of the sealed
refrigeration system and should be replaced by a
professional service technician. You can,
however, test the compressor and certain
components. Unplug the unit and remove the access
cover to the mechanical housing. A small box
mounted on the side of the compressor protects
the relay, overload protector and capacitor.
Release the wire retaining clip that holds the
cover in place and slip off the cover and the
clip.
23