Specifications

SYMPTOM POSSIBLE CAUSE PROCEDURE
UNIT TOO COLD
1. TEMPERATURE CONTROL SET TOO
LOW.
1. ADJUST CONTROL.
2. TEMPERATURE CONTROL FAULTY. 2. TEST CONTROL. SEE #4
MOISTURE AROUND DOOR OR
FRAME.
1. BREAKER STRIPS FAULTY. 1. INSPECT STRIPS.
2. TEMPERATURE SET TOO LOW 2. RAISE SETTING.
ICE IN DRAIN PAN OR WATER IN
BOTTOM OF UNIT OR FLOOR
1. DRAIN TUBE CLOGGED. 1. CLEAN DRAIN. SEE #2
2. UNIT NOT LEVEL
2. ADJUST LEVELING FEET SEE DIAGRAM
A PAGE 13.
UNIT NOISY 1. UNIT NOT LEVEL
ADJUST LEVELING FEET SEE DIAGRAM
A PAGE 13.
2. COMPRESSOR MOUNTINGS LOOSE OR
HARDENED.
2. TIGHTEN OR REPLACE COMPRESSOR
MOUNTINGS.
3. CONDENSER FAN DAMAGED OR
FITTING FAN SHROUD.
3. INSPECT CONDENSER FAN. SEE #7
4. EVAPORATOR FAN DAMAGED OR
HITTING FAN SHROUD.
4. INSPECT EVAPORATOR FAN. SEE #5
5. MECHANICAL COMPARTMENT LOUVER
RATTLING.
5. BEND OR ALIGN TABS TO REDUCE
NOISE. REPLACE IF NECESSARY.
19