Specifications
Figure B - Temperature control adjustments
The control knob allows for temperature
adjustments, with in the cabinet only. Turning
the knob clockwise will result in increased
cooling. Keep the arrow on the knob pointed
within the green arc. Turning it clockwise
beyond the green can result in freeze-up, while
turning it counterclockwise beyond the green
will shut the compressor off. If your cabinet
temperature remains to warm and your
temperature control is at the maximum setting
you may need to adjust the pressure control.
Your units pressure control should be set at
the time of installation by a qualified
installation contractor. If minor adjustments
are needed at a later date, adjust control by
turning the right adjusting screw clockwise
(1/4 turn at a time) to a lower number for
colder temperature and counterclockwise to a
higher number for warmer temperature.
Note: Numbers are pounds of pressure not degrees F.
Note: Do not adjust the differential screw (Left screw).
Note: Temperature Controls located behind louver on top of unit.
14