Use and Care Manual
7
User Maintenance
WARNING
Service on this boiler should be undertaken only by trained and skilled personnel from a qualied service 
agency.  Inspections should  be  performed at  intervals specied  in  Installation, Operating  and Service 
Instructions and this manual. Maintain manuals in a legible condition.
Keep boiler area clear and free of combustible materials, gasoline and other ammable vapors and liquids.
Do not place any obstructions in boiler room that will hinder ow of combustion and ventilation air.
A.  General Housekeeping (Continuous).
1.  Keep boiler area clear and free of combustible 
materials and obstructions to the free ow of 
combustion and ventilation air to the boiler.
2.  Do not store or use gasoline, other ammable 
vapors, liquids or sources of hydrocarbons in the 
vicinity of the boiler or any other appliance.
3.  Do not store or use halogen-containing products 
(bleaches, cleaners, fabric softeners, refrigerants, 
chemicals, etc.) in the vicinity of the boiler. 
B.  Inspect Inlet Air and Vent System (Monthly). Check 
the following. If corrective action is required contact 
qualied service agency.
1. Blocked vent switch must be attached to the canopy.
2.  Vent pipe must be full round shape, showing no 
damage from impact or excessive temperature.
3.  All vent pipe joints must be secure.
4.  Horizontal runs must not sag.
5.  The vent system must be free of corrosion and other 
deterioration.
6.  Supports must not be loose or broken.
C.  Inspect Pilot and Main Burner Flames (Monthly).
1.  Remove jacket front panel. 
2.  View ames through burner access panel. See 
Figure 1.
3.  Adjust thermostat to highest setting.
4.  Check pilot ame. See Figure 4. The pilot produces 
one ame. The ame should be steady, medium 
hard blue enveloping 
3
/8 to ½ inch of sensing probe. 
If ame is yellow and lazy, follow instructions TO 
TURN OFF GAS TO APPLIANCE (see Figure 2), 
and contact qualied service agency.
5.  Check main burner ames. See Figure 5. Flame 
should have clearly dened inner cone with no 
yellow tipping. Orange-yellow streaks caused 
by dust should not be confused with true yellow 
tipping. If yellow ames are observed, follow 
instructions TO TURN OFF GAS TO APPLIANCE 
(see Figure 2), and contact qualied service agency.
6.  Adjust thermostat to normal setting.
D. Schedule Inspection by Qualied Service Agency 
(Annual or at Beginning of Heating Season). For 
continued safe operation a qualied service agency 
must provide a more detailed inspection of burners, heat 
exchanger and vent system, and provide maintenance 
as specied in Installation, Operating and Service 
Instructions.