Product Overview
A - Straight
B - Candycane
C - Flare
D - Candycane w/ Flare
E - Offset w/Flare
F - Offset Straight
Valve Specifications
Minimum/Maximum P to reverse 15/440 psi (V12 - 15/400 psi)
Maximum normal working pressure 680 psi (V12 - 500 psi)
Maximum abnormal pressure (fatigue) 833 psi (V1 - V10 only)
Minimum burst pressure 2500 psi
Maximum operating temperature 250° F
Maximum brazing temperature
1
250° F
Maximum sound level
2
50dB
Maximum external leakage
3
0.1 ounce per year
Known compatible refrigerants
R12, R22, R134a, R500, R502, R410a, R407c,
R404a
Minimum life 165,000 cycles
Mounting position Any
1
Measured on valve body at connection tube interface.
2
A-scale, 0.0002 Dyne/cm2 reference, 12" from valve, 40 dB or less background.
3
Leakage measured at 400 psig internal pressure.
Valve Selection Guide
Valve Type
Capacity,
Tons
Minimum to
Nominal R22
Internal Leakage,
cc/min
Tube
Style
Standard Connections Tube Sizes
Female I.D., Inches
Discharge Suction,L,R
V1 0.4 to 1 400 to 2000 A, B 1/4", 5/16", 3/8", 3/8", 1/2"
V2 0.75 to 2 400 to 2000 A, B 1/4", 5/16", 3/8", 3/8", 1/2"
V2 1 to 2.5 400 to 2000 C, D 3/8", 1/2" 5/8"
V3 1 to 2.8 (3 on
3/4)
500 to 2000 E 3/8", 1/2" 5/8", 3/4"
V4 1 to 4 500 to 4000 A 1/2", 5/8", 3/4" 3/4", 7/8"
V6 1/ 5.5 500 to 4000 A 3/8", 1/2", 5/8",
3/4"
3/4", 7/8"
V10 3 to 8.5 (9.5
on 1/8)
800 to 6000 A 1/2", 5/8", 3/4",
7/8"
7/8", 1 1/8"
V12 5 to 12 1500 to 15000 F 1 1/8" 1 3/8"
Minimum capacities shown are
recommendations based on standard
ARI conditions (45° F Evap. 130° F
Cond., 10°F SH, 10° F SC, 64.8 Btu/lb.
H) and reciprocating compressors.
System manufacturers are encouraged
to conduct their own application
testing to assure positive valve
reversals under all anticipated
operating conditions.
Nominal Capacity shown at 2 psig
suction pressure drop. Maximum
capacity not shown; Suction pressure
drop vs. valve type used must be
rationalized.
Valves for systems using alternate compressor
styles and/or high efficiency, large volume coils
should be evaluated for proper sizing to ensure
minimum valve pressure drop and capacity for
reliable reversals.
Male O.D. tube sizes are also available.