Specifications
46
 6.1. Connections to be made by the 
user.
Hook-up  must  be  carried  out  by  qualified 
personnel  in  full  accordance  with  federal, 
state and local regulations.
6.1.1. Water supply  (Fig.6)
This  equipment  is  to  be  installed  to 
comply with the applicable federal, state 
or local plumbing codes.
Connections must be installed close to the machine.
L Water drainage pipe 1, having a minimum internal 
diameter of 30 mm, equipped with a water-trap 
accessible for inspection.
L Water supply pipe 2, with a 3/8"G cut-off tap.
Make sure that the maximum supply pressu-
re does not exceed 6.5 bar; otherwise, install 
a pressure reducer.
6.1.2. Electric supply
The machine is supplied ready for connection 
according to the required electrical specifications.
Before connecting the machine ensure that the plate 
details comply with those of the electric distribution 
network.
The  electrical  connection  cable  must  be  directly 
connected to the connection provided according to 
current legislation. Ensure that the earthing system 
is efficient and in compliance with current legal re-
quirements.
The earthing system and  the lightening protection 
system  must  be  realized  in  accordance  with  the 
provisions of current legislation.
For the supply network use a cable in compliance with 
standards with protective conductor (earthing wire).
For three-phase power use a cable with 5 conductors 
( 3 phases + neutral + earth).
For single phase power supply use a cable with 3 
conductors (phase + neutral + earth).
In both cases it is necessary to provide an automatic 
differential switch (Fig. 6) at the start of the power 
cable, complete with magnetic release elements in 
accordance with the identification plate details (Fig. 
1). The contacts must have an opening of equal or 
over 3 mm and with dispersed current protection of 
30 mA.
Remember that each machine must be fitted with its 
own safety elements.
WARNING:
Should the power supply cable be damaged 
it is to be replaced by the manufacturer or by 
its technical assistance service or by person 
with equivalent qualification, in order to pre-
vent any risks.
6. INSTALLATION
The appliance is only to be installed in lo-
cations where use and maintenance is restricted to 
trained personnel.
The machines are fitted with height adjustable feet.
The support surface shall be levelled, dry, smooth, 
steady and stable and at such a height that the cup-
warming surface is at over 150 cm from ground. Do 
not  use  water  jets  or  install  where  water  jets  are 
used.
In order to guarantee normal operation, the machine 
must  be  installed  in  areas that the  environmental 
temperature is between  +5°C y +32°C end humidity 
of not over 70%.
It does not need to be anchored to the surface and it 
does not require any technical operations to dampen 
vibrations in order to operate properly.
It is recommended to leave the area around the ma-
chine free to facilitate its use and the performance 
of any maintenance operations.
If the machine is wet or very damp, wait until it is 
completely dry before installing or using it.  It is always 
necessary to request an accurate control to qualified 
service people in order to find any possible damage 
to the electric components.
Reserve an area near the machine for the installa-
tion of the coffee grinding and dosage machine (see 
relevant documentation).
The machine is usually equipped with a water sof-
tener, type DP2 or DP4, which must be connected 
by  the  user  in  compliance  with  the  laws  in  force.  
Should a different softener be installed, refer to the 
documentation of the relevant product.
A dreg drawer should be fitted by the installer. 