FOR CLASS I VEHICULAR GATE OPERATORS
www.ramsetinc.
TABLE OF CONTENTS Important Safety Requirements & Instructions …………………………………………….........……. 1 Responsibilities of Installers and Technicians …………………………………………………………. 2 Important Safety Requirements by UL Standards …………………………………….………………. 3 Classes of Vehicular Gate Operators/Recommended Electrical Connection …..………………….. 4 General Specifications ………………………………………………………………………………….... 5 Installation Specifications ………………………………………………………………………………...
RAM 30 UL RAMSET RESPONSIBILITIES OF INSTALLERS AND TECHNICIANS INSTALLATION: • READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE ATTEMPTING ANY INSTALLATION. • DO NOT EXCEED THE EQUIPMENT SPECIFICATIONS. • INSURE A SAFE AND PROPER INSTALLATION. • INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE UL 325 SPECIFICATIONS. • MAKE SURE TO ELIMINATE ANY PINCH POINTS EXISTING ON THE INSTALLATION. (ie. ROLLERS, ARMS…etc.) SAFETY DEVICES: • REMOVE OR PROTECT ALL PINCH POINTS FROM GATE OPERATORS ARMS.
IMPORTANT SAFETY REQUIREMENTS BY UL STANDARDS Prior to installation of a Ramset gate operator, the following must be observed: (per UL 325.51.8.4). a) Install the vehicular gate operator only when: 1) The Vehicular Gate Operator is appropriate for the construction of the gate and the usage class of the gate. 2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m.) above the ground to prevent a 2 1/4 inch (57.15 mm.
RAM 30 UL RAMSET CLASSES OF VEHICULAR GATE OPERATORS Vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.
RAM 30 UL RAMSET RAM 30 UL GENERAL SPECIFICATIONS: Heavy Duty Torque-limiter: Absorbs high impacts on gates to minimize damage on gear reducer. Maximum Gate Size & Weight: 12' @ 400 lbs. Gate Traveling Speed: Approx. 90º opening in 16 sec. Cycles: 30 per hour. / Shipping: 75 lbs. Application: Residential. Heavy Duty Worm Gear: Lubricated by oil bath gives smooth and quiet operation. WARNING: Do not exceed the specifications. Electric Motor: 1/2 hp 120 VAC 5.
RAM 30 UL RAMSET INSTALLATION SPECIFICATIONS CONCRETE PAD CONSTRUCTION: Dimensions given for the pad are based on soil bearing shear of 2000 P.S.F. These figures may have to be adjusted depending on local soil conditions. 1. Construct form for mounting pad according to dimensions shown in Figure 1 and 2. STANDARD INSTALLATION Gates from: 4' to 12' [ 23" ] COMPACT INSTALLATION Gates up to 10' [ 17" ] 2. Locate mounting pad according to dimensions given in illustration. 3. Level top edge of form. 4.
RAM 30 UL RAMSET HOOKUP ELECTRICAL POWER Figure 3 Outlet Leads NOTE: Hookup your electrical 15 amp wires direct to outlet. GATE TRAVEL ADJUSTMENT Figure 4 Cam Slams Limit Switches Gate travel is adjusted by loosening the limit Cams and positioning them until proper gate travel has been achieved. www.ramsetinc.
RAM 30 UL RAMSET STANDARD INSTALLATION FOR GATES FROM 4' TO 12' IN LENGTH Figure 5 SPACE REQUIRED FOR A STANDARD GATE IN THE OPEN POSITION Figure 6 8 www.ramsetinc.
RAM 30 UL RAMSET COMPACT INSTALLATION FOR GATES UP TO 10' IN LENGTH Figure 7 MINIMUM SPACE REQUIRED FOR COMPACT INSTALLATION 20" minimum space required between, open gate and wall for this compact installation. Figure 8 www.ramsetinc.
RAM 30 UL RAMSET SENSOR INSTALLATION Ramset Gate Operators should not be installed without non-contact sensing devices such as Loop Detectors, photo electric sensors or the equivalent. WARNING: A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installation to comply with UL325. Reversing Loops on the ground floor, prevents gate from closing when vehicle is in loop area.
PUSHBUTTON CONTROLS Three pushbuttons are located under the dip switches for operation of the gate (see Figure 11). The opening, stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator. Opening Pressing this button will cause the gate to open. L.E.D.’s light up when Opening, Closing or Stopped Stop Pressing this button will cause the gate to stop moving.
RAM 30 UL RAMSET DIP SWITCH CONFIGURATION Figure 12 Dip Switch Up for "ON" Dip Switch Down for "OFF" DIP SWITCH "A" Dip Switch "A" 1, 2 & 3; AUTOMATIC TIMER TO CLOSE GATE ‘0’ is “OFF” Switch (Constant warning when gate is in motion). ‘1’ is “ON” 1 2 3 Gate Open Duration: Sw. 1 1 1 60 seconds OFF No effect.
RAM 30 UL RAMSET DIP SWITCH "C" Dip Switch "C" 7; “LEFT / RIGHT” Dip Switch "C" 1; “SECURE CLOSE” Sw. Sw. Function: OFF Normal Operation ON When power is lost, then regained, control board checks status of the gate. If open and safety devices are cleared, gate will close automatically. Function: OFF Left hand installations - All operators come factory set for left hand operation. ON Right hand installations - Reverses motor & limit switches without moving any wires.
RAM 30 UL RAMSET TERMINAL STRIP CONNECTION FOR OPTIONAL ACCESSORIES Figure 13 14 www.ramsetinc.
Terminal # 1 - COMMON: Low voltage common. sound for 6 minutes and the control board will not accept any commands. After the 6 minutes the 24 VDC is removed from the alarm connection and the board resets to normal operation. Terminal # 2 - REV LOOP: Used with safety edge mounted on post or back of gate. TERMINAL STRIP CONNECTIONS Stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate.
RAM 30 UL RAMSET RAMSET “INTELLIGATE” CONTROL BOARD Introduction: sary board modifications between 110 VAC and Ramset’s “Intelligate” Control Board works 220 VAC single-phase applications. with Sliding, Swinging and Overhead vehicular functions of the Control Board are: 0 - 60 seconds gate operators. It is controlled by a program- automatic close timer, self adjusting E.R.D.
RAM 30 UL RAMSET WIRE BOARD CONNECTIONS JP9 - Input Power: 1,2) 24 VAC power. Connection from external transformer to power Control Board. JP3 - 3 Button: 1) Close 2) Stop 3) Open 4) Common Used with a 3-button station to open, stop, and close the gate. The open and close are normally open connections and the stop is a normally closed connection, remove jumper wire when connecting 3 button station. Common and stop are also used with a photo eye used to protect the backplane of the operators.
RAM 30 UL RAMSET RAM 30 UL Exploded View 57 Figure 15 8 46 62 74 17 2 3 23 28 27 20 15 25 16 26 52 33 68 10 8 11 4 18 4 17 67 32 26 22 21 47 61 2 42 24 17 19 65 50 18 5 40 29 51 56 61 61 53 61 61 53 39 61 19 2 41 38 39 3 63 41 64 55 10 2 1 84 38 9 12 4 66 31 58 2 14 61 4 44 43 2 36 82 37 45 94 70 42 10 4 34 14 2 2 84 35 69 6 59 60 2 49 13 2 48 30 14 4 18 www.ramsetinc.
RAM 30 UL RAMSET BILL OF MATERIAL FOR: RAM 30 UL ITEM PART # PART DESCRIPTION RAM 30 UL 1 50-027 Gear Reducer Size 40 60:1 1 2 50-039 20 Pin Edge Connector 1 3 50-050 40 b 12 7/8" Sprocket 1 4 50-069 Limit Switch 00h-3 2 5 50-084 # 40 Drive Chain 1 6 50-091 # 6 x 1" Machine Screw 2 7 50-092 3/8-16 x 1 1/2" Hex Head Bolt 4 8 50-095 5/16-18 x 3/4" Hex Head Bolt 13 9 50-096 5/16" Lock Washer 8 10 50-097 5/16" Flat Washer 14 11 50-103 3/8-18 Hex Head Lock Nut 4
RAM 30 UL RAMSET BILL OF MATERIAL FOR: RAM 30 UL 20 ITEM PART # PART DESCRIPTION RAM 30 UL 45 50-304 120/240 Intelligate Transformer 1 46 50-337 1/2" x 1-1/2" Hex Head Bolt 1 47 50-339 1" x 2" Plastic Cap 2 48 50-401 10 Ga Heavy Duty Metal Chassis 1 49 50-402 Board Lexan Glass Cover 1 50 50-403 Polyethylene Cover 1 51 50-404 3/4" x 10" Limit Switch Shaft 1 52 50-405 40A27 Sprocket 1 53 50-406 3/4" Limit Switch Cam 2 54 50-407 1/2" x 1" Cast Iron Pulley 2 55 5
RAMSET CONDITION RAM 30 UL TROUBLESHOOTING TABLE SOLUTION POSSIBLE CAUSES NO LIGHTS ARE 'ON' 1. Circuit breaker popped. 2. 1/2 amp. fuse blown. 3. Power supply damaged on control Board. 1. Reset circuit breaker. 2. Replace 1/2 amp. fuse. 3. Return Control Board for repair. GATE MOVES A COUPLE OF FEET AND THEN REVERSES 1. E.R.D. too sensitive. 1. A) for 1/2 hp motors: turn dip switch "A" 4 'On'. "EXIT" L.E.D. IS ALWAYS 'ON' 1. Faulty accessory connected to the "Exit". 1.
RAM 30 UL RAMSET GATE ENTRANCE SAFETY PRECAUTIONS WARNING: 1. Never let children operate or play with gate controls. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance. 3. Always keep people, children and objects away from the gate while the gate is in operation. No one should cross the area of a moving gate. 4.
RAM 30 UL Opening the way… Important information for the homeowner Ask your technician about all the features of our new Ramset operator. Safety devices, such as reverse loops, phantom loops, photo eyes, or miller edges must be installed on your gate before the operator may be used. Ask your technician which safety devices best suit your safety needs. Read your warranty certificate and fill out your warranty extension card.
RAM 30 UL RAMSET RAMSET OPTIONAL ACCESSORIES 20-05 Ramset Mounting Post for Access Control 50-40 Ramset Remote Control Transmitter Ramset Radio Receiver Ramset ILD-24 Plug-in Loop Detectors Ramset Fire Box EMERGENCY ENTRY BOX RKLE Ramset Keyless Entry System 24 Ramset Key Switch Box Ramset Magnetic Lock www.ramsetinc.com Ramset RPI Provides power for a 1/2 hp gate operator and accessories. For approx. 50 cycles.