MSDS
MSDS # 00055.0001
MATERIAL
SAFETY DATA
SHEET
Olin MSDS No.:
00055.0001
Revision No.: 21
Revision Date:
7/30/14
Supercedes: 2/21/14
1. PRODUCT AND COMPANY IDENTIFICATION
Product Name:
CARTRIDGES FOR POWER DEVICES
Chemical Name:
Mixture – Metal Alloy
Synonyms:
Centerfire Powertool Loaded Round, Rimfire Cartridge for Power Device, 22, 25, 27, 32, 38 Caliber
Powertool Round, Power Load, Blank Power Load and/or Booster, Powder Load
Chemical Family:
Metal mixture
Formula:
Not applicable - mixture
Product Use/ Description:
Centerfire Powertool Loaded Round
COMPANY ADDRESS
MSDS Control Group
Olin Corporation
Winchester Division, Inc.
600 Powder Mill Road
East Alton, IL 62024-1197
www.winchester.com
TECHNICAL
INFORMATION:
618-258-3507
EMERGENCY TELEPH
ONE NUMBER:
US/Canada: 1-800-424-9300
Outside US/Canada: 703-527-3887
Customer #: ccn24728
2. COMPOSITION / INFORMATION ON INGREDIENTS
CAS Number
Components
% By Weight
EINECS/ ELINCS #
EU Classification
Symbol
R
-
Phrase
7439-89-6 Iron 0 – 97 231–096-4 None None
7440-50-8 Copper 50 - 65 231-159-6 None None
7440-66-6 Zinc 15 - 32 231-175-3 F (as dust or
powder)
R 15-17
9004-70-0 Nitrocellulose 7 - 13 Not listed E* R 1-3
55-63-0 Nitroglycerin 0.5 - 2 200-240-8 E, T+, N R 3-26/27/28-33-
51-53
15245-44-0 Normal Lead
styphnate
0.1 - 1 239-290-0 E, T, N R61-3-20/22-33-
50/53-62
*This material is not listed in Annex 1 of Directive 88/379/EEC. Olin has classified the material according to the conventional method based
upon information from similar materials.
OSHA REGULATORY STATUS: Explosive
3. HAZARDS IDENTIFICATION
CAUTION!
EXPLOSIVE. KEEP AWAY FROM HEAT. DO NOT SUBJECT TO MECHANICAL SHOCK. PARTICLES FROM FIRING MAY BE
HARMFUL IF INHALED. DO NOT TAKE INTERNALLY.
HAZARD RATINGS (for dus
t or fume)
Degree of hazard (0 = low, 4 = extreme)
Hazardous Materials Identification System (HMIS) Health: 0 Flammability: 0 Physical Hazard:
Explosive: 2
National Fire Protection Association (NFPA) Mixture. Not rated.
HUMAN THRESHOLD RESPONSE DATA
Odor Threshold: Unknown
Irritation Threshold: Unknown
Immediately Dangerous to Life or Health (IDLH) Value(s): The IDLH for this product is not known. The IDLH for copper and lead
is 100 mg/m
3
. The IDLH for nitroglycerin is 75 mg/m
3
.
POTENTIAL HE
ALTH EFFECTS