Operation Manual
Original User Guide | Impulse 2.0 Pedelec Version 3 EN-81
Description Cause Remedy
The display is misted up Moisture has got in. Dry out the pedelec complete with display at room temperature (19–21°C). If the display is still misted up,
contact your DCW/RU dealer. The display may have to be replaced.
Motor assist level is too weak a) Climb Assist is set too low. a) Change the value 6.8.2.10 Climb assist Page EN-52.
b)Batteryisat. b) Install new/charged battery 8.3.1 Charging the battery Page EN-75.
c) Unsuitable ride profile. c) Please ask your DCW/RU dealer. They can set another ride profile on your pedelec.
Motor idles a) Gear changing is not properly
set.
a) Check the setting. If necessary, ask your DCW/RU dealer.
b)Chain/belthascomeo. b) Lift the chain/belt on to the sprocket and adjust the tension. If necessary, ask your DCW/RU dealer 3.7.1
Chain tension Page EN-20 3.8.1 Belt tension Page EN-22.
Power assist sporadically cuts out a) The spoke magnet has
slipped.
a) Check whether the spoke magnet has slipped. It
should be as close as possible to the speed sensor
on the chain stay (max. 10 mm). Align the magnet
on the marker point with the speed sensor.
Spoke magnet
Speed sensor
b) Climb Assist is set too high. b) Change the value 6.8.2.10 Climb assist Page
EN-52.