Operation Manual

Original User Guide | Impulse 2.0 Pedelec Version 3 EN-75
Charger type 4 for down tube battery
Battery voltage
36 V
AC input voltage
230 V
Frequency
50 Hz
Max. DC output voltage
42 V
Max. charge current
4 A
Dimensions ( L I W I H)
202 mm I 90 mm I 55 mm
Operating temperature
-10°C to +40°C
Recommended storage tem-
perature
0 to 20°C
Weight
745 g
Protection class
The charger is only intended to be used
indoors. Keep the charger away from
rain and moisture. If water gets into the
charger there is a risk of electric shock.
LEDs
Mains connector
Charging cable
Power cable
!
Charger connected to
power supply
|thegreenLEDashes
Battery being charged
|thegreenLEDashes
Fully charged
| the green LED continually ON
Charging fault
|theredLEDashes
Description
of charging
indicator
8.3 Functions
8.3.1 Charging the battery
DANGER
Readandfollowtheinformationonthechargerspecicationplate,
otherwise there is a risk of misuse resulting in serious injuries.
The battery can remain on the pedelec during charging. It
can also be removed and charged elsewhere.
Charging
DANGER
Damaged batteries must not be charged.
The battery can remain on the pedelec during charging or
you can remove the battery and charge it elsewhere.
Before charging, please remove the plastic foil from the
battery charger and charging station type 1.