User's Manual
Rajant Corporation BreadCrumb
®
LX User Guide
Version 1.06 June 25, 2008
- 26 -
6.1.2 BREADCRUMB CANNOT CONNECT TO BCWN
Table 3. BreadCrumb Cannot Connect to BCWN
Problem Resolution
Discharged batteries can cause the BreadCrumb to
appear to power up, but not be able to establish
connectivity to the BCWN.
When deploying the BCWN, ensure that the batteries
should be fully charged.
On rare occasions, the PCMCIA cards within a
BreadCrumb can work loose, resulting in the
BreadCrumb’s not being able to establish connectivity
to the BCWN.
Open the BreadCrumb’s case and verify that the
PCMCIA cards are securely seated in the PCMCIA
slots.
When using external antennas, faulty cable connections
or crimped cables can result in difficulty establishing
and maintaining network connectivity.
Check antenna cables and their connections to the
BreadCrumb.